Replacing Components; Replacing A Fan Module - Cisco Nexus 93180YC-FX Hardware Installation Manual

Hide thumbs Also See for Nexus 93180YC-FX:
Table of Contents

Advertisement

Replacing Components

Replacing a Fan Module

You can replace one of the four fan modules at a time while the switch is operating so long as you perform
the replacement within one minute. If you cannot perform the replacement within one minute, leave the original
fan module in the chassis to maintain the designed airflow until you have the replacement fan module on hand
and can perform the replacement.
Caution
If you are replacing a module during operations, be sure that the replacement fan module has the correct
direction of airflow, which means that it has the same airflow direction as the other modules in the chassis.
Also, be sure that the airflow direction takes in air from a cold aisle and exhausts to a hot aisle. Otherwise,
the switch can overheat and shutdown.
If you are changing the airflow direction of all the modules in the chassis, you must shutdown the switch
before replacing all the fan and power supply modules with modules using the other airflow direction.
During operations, all of the modules must have the same direction of airflow.
Replacing a Fan Module, page 29
Replacing a Power Supply Module, page 30
C H A P T E R
Cisco Nexus 93180YC-FX NX-OS Mode Switch Hardware Installation Guide
5
29

Advertisement

Table of Contents
loading

Table of Contents