Cisco Catalyst 3750-E Software Configuration Manual page 790

Hide thumbs Also See for Catalyst 3750-E:
Table of Contents

Advertisement

Configuring SNMP
Beginning in privileged EXEC mode, follow these steps to configure the switch to send traps or informs
to a host:
Command
Step 1
configure terminal
Step 2
snmp-server engineID remote
ip-address engineid-string
Step 3
snmp-server user username
groupname {remote host [udp-port
port]} {v1 [access access-list] | v2c
[access access-list] | v3 [encrypted]
[access access-list] [auth {md5 | sha}
auth-password]}
Step 4
snmp-server group groupname {v1 |
v2c | v3 {auth | noauth | priv}} [read
readview] [write writeview] [notify
notifyview] [access access-list]
Step 5
snmp-server host host-addr
[informs | traps] [version {1 | 2c | 3
{auth | noauth | priv}}]
community-string [notification-type]
Catalyst 3750-E and 3560-E Switch Software Configuration Guide
33-14
Purpose
Enter global configuration mode.
Specify the engine ID for the remote host.
Configure an SNMP user to be associated with the remote host created in
Step 2.
Note
You cannot configure a remote user for an address without first
configuring the engine ID for the remote host. Otherwise, you
receive an error message, and the command is not executed.
Configure an SNMP group.
Specify the recipient of an SNMP trap operation.
For host-addr, specify the name or Internet address of the host (the
targeted recipient).
(Optional) Enter informs to send SNMP informs to the host.
(Optional) Enter traps (the default) to send SNMP traps to the host.
(Optional) Specify the SNMP version (1, 2c, or 3). SNMPv1 does
not support informs.
(Optional) For Version 3, select authentication level auth, noauth, or
priv.
For community-string, when version 1 or version 2c is specified,
enter the password-like community string sent with the notification
operation. When version 3 is specified, enter the SNMPv3 username.
The @ symbol is used for delimiting the context information.
Note
Avoid using the @ symbol as part of the SNMP community string
when configuring this command.
(Optional) For notification-type, use the keywords listed in
Table 33-5 on page
33-12. If no type is specified, all notifications are
sent.
Chapter 33
Configuring SNMP
OL-9775-08

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst3560-e

Table of Contents