RELAY OPERATION

Normal
Alarm Relay
Closed
1
For information on Trouble conditions, see the Troubleshooting section.

TROUBLESHOOTING

NORMAL
Alarm Relay
Closed
Red LED
Off
*TROUBLE CONDITIONS:
1
Self-Test Failure conditions:
• PIR self-test failure: The sensor is disabled.
• Temperature compensation failure: The temperature compensation is
disabled.
Depending on the Trouble condition, take the following corrective actions:
• Verify the power supply is sufficient (at least 9V at the sensor).
• Cycle power to the sensor.
• Walk test the sensor.
If the Trouble condition does not clear, replace the sensor.

SPECIFICATIONS

Range: 40' x 56' / 12 m x 17 m
Wall Mounting Height: 6'9" – 8'9" (2.1 m - 2.7 m); Optimal 7'6" (2.3 m)
Power: 9.0-15 VDC (UL: 9.5-15 VDC); 7 mA typical, 12 mA maximum;
AC Ripple: 3 V peak-to-peak at nominal 12 VDC
Alarm Relay: Energized Form A; 90 mA, 15 VDC, 22 Ohms resistance
maximum. Alarm Relay Duration: 3 seconds
RFI Immunity: 20V/m 10-1000MHz, 15V/m 1000-2700MHz
PIR White Light Immunity: 2000 Lux typical
Operating Temperature: 14° to 131° F / -10° to 55° C
Relative Humidity: 5 to 93% (UL tested at 93%); non-condensing
Temperature Compensation: Advanced Dual Slope
Dimensions: 3.39" H x 2.24" W x 1.71" D /
8.6 cm H x 5.7 cm W x 4.35 cm D
Weight: 2.15 oz / 61 g (net weight)
ACCESSORIES
SMB-10*
Swivel Mount Bracket
(P/N 0-000-110-01)
SMB-10C*
Swivel Mount Ceiling Bracket
(P/N 0-000-111-01)
* These accessories have not been evaluated by UL.
www.honeywell.com/security/hsc/resources/wa or contact your local authorized Honeywell representative for product warranty information.
© 2013 Honeywell International Inc. Honeywell is a registered trademark of Honeywell International Inc. All other trademarks are the properties of their respective owners.
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
www.honeywell.com/security
SENSOR STATUS
1
Intrusion
Trouble
Open
Open
TROUBLE*
1
Self-Test Failure
Open
Flashing
For the latest documentation and online support information, please go to:
http://www.security.honeywell.com/hsc/resources/MyWebTech/
For the latest U.S. warranty information, please go to:
APPROVAL LISTINGS
• FCC part 15, Class B verified
• IC ICES-003, Class B verified
• ETL Listed to UL 639
• cETL Listed to ULC S306
Product must be tested at least once each year.
All wiring must be in accordance with: the National Electrical
Code (ANSI/NFPA70); the Canadian Electrical Code, Part I
(where applicable); UL681, Standard for Installation and
Classification of Burglar and Holdup Alarm Systems; ULC-
S302, Standard for Installation and Classification of Burglar
Alarm Systems for Financial and Commercial Premises, Safes
and Vaults; ULC-S310, Standard for Installation and
Classification of Residential Burglar Alarm Systems; local
codes and the authorities having jurisdiction.
The products are intended to be powered by a power-limited
output of a UL/CUL Listed Burglar Alarm control unit, or via a
Listed UL603/ULC-S318 power-limited power supply that
provides 4 hours of standby power.
The sensor must be mounted indoors, within the protected
premises, and on a wooden stud, solid wood or with a robust
wall anchor.
UL Notes: All interconnecting devices must be UL Listed. The pet
immunity feature has not been evaluated by UL.
FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized
by the Installation Instructions or User's Manual. Unauthorized changes or modifications
could void the user's authority to operate the equipment.
CLASS B DIGITAL DEVICE STATEMENT
This equipment has been tested to FCC requirements and has been found acceptable for
use. The FCC requires the following statement for your information:
This equipment generates and uses radio frequency energy and if not installed and used
properly, that is, in strict accordance with the manufacturer's instructions, may cause
interference to radio and television reception. It has been type tested and found to comply
with the limits for a Class B computing device in accordance with the specifications in Part
15 of FCC Rules, which are designed to provide reasonable protection against such
interference in a residential installation. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause interference to radio or
television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
If using an indoor antenna, have a quality outdoor antenna installed.
Reorient the receiving antenna until interference is reduced or eliminated.
Move the radio or television receiver away from the receiver/control.
Move the antenna leads away from any wire runs to the receiver/control.
Plug the receiver/control into a different outlet so that it and the radio or television
receiver are on different branch circuits.
Consult the dealer or an experienced radio/TV technician for help.
INDUSTRY CANADA CLASS B STATEMENT
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and RSS-210 of Industry Canada.
Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) This device must accept any interference received, including
interference that may cause undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS-210 des Industries
For the latest documentation and online support information, please go to:
Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit
http://www.security.honeywell.com/hsc/resources/MyWebTech/
pas causer d'interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue
Ê800-19276-01gŠ
800-19276-01 09/14 Rev B

Advertisement

loading