240W Single Output Switching Power Supply
HLG-240H-12 A
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
C : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal
potentiometer.
D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.

SPECIFICATION

MODEL
DC VOLTAGE
CONSTANT CURRENT REGION
RATED CURRENT
RATED POWER
RIPPLE & NOISE (max.)
Note.2
VOLTAGE ADJ. RANGE
Note.6
OUTPUT
CURRENT ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
Note.8
SETUP, RISE TIME
Note.9
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (
Typ
.)
LEAKAGE CURRENT
OVER CURRENT
Note.4
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
Note.7
SAFETY &
WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
NOTE
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the
6. Type A and type C only.
7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.
110
F
SELV
HLG-240H-12
HLG-240H-15
HLG-240H-20
12V
15V
20V
6 ~12V
7.5 ~ 15V
10 ~ 20V
Note.4
16A
15A
12A
192W
225W
240W
150mVp-p
150mVp-p
150mVp-p
11.2 ~ 12.8V
14 ~ 16V
18.6 ~ 21.4V
Can be adjusted by internal
potentiometer
8 ~ 16A
7.5 ~ 15A
6 ~ 12A
2.5%
2.0%
1.0%
0.5%
0.5%
0.5%
2.0%
1.5%
1.0%
2500ms, 80ms at full load
230VAC /115VAC
15ms at full load
230VAC /115VAC
90 ~ 305VAC
127 ~ 431VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
90%
90%
92%
4A / 115VAC
2A / 230VAC
COLD START 75A/230VAC
<0.75mA / 277VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
13.5 ~ 18V
17.5 ~ 21.5V 23.5 ~ 27.5V 27 ~ 34V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
105
5
(TSW1)
95
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-40 ~ +70
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/
(0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL1012, CAN/CSA-C22.2 No. 107.1-01, UL8750, CSA C22.2 No. 250.0-08, TUV EN61347-1, EN61347-2-13 independent
(except for HLG-240H C type), UL60950-1, UL8750, TUV EN60950-1, IP65 or IP67, J61347-1, J61347-2-13 approved
I/P-O/P:3.75KVAC
I/P-FG:1.88KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
207.9Khrs min.
MIL-HDBK-217F (25 )
244.2*68*38.8mm (L*W*H)(HLG-240H-Blank/A/B)
1.3Kg; 12pcs/16.6Kg/0.84CUFT(HLG-240-Blank/A/B)
H L G - 2 4 0 H

Features :

Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistance)
Suitable for LED lighting and street lighting applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
5 years warranty (Note.10)
IP65 IP67
HLG-240H-24
HLG-240H-30
HLG-240H-36
24V
30V
36V
12 ~ 24V
15 ~ 30V
18 ~ 36V
6.7A
10A
8A
240W
240W
241.2W
250mVp-p
150mVp-p
200mVp-p
22.4 ~ 25.6V
28 ~ 32V
33.5 ~ 38.5V
or through output cable
3.3 ~ 6.7A
5 ~ 10A
4 ~ 8A
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
93%
93%
93%
1.2A / 277VAC
33 ~ 39V
43 ~ 49V
5
(TSW1)
O/P-FG:0.5KVAC
251*68*38.8mm (L*W*H)(HLG-240H-C)
1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240-C)
of ambient temperature.
for more details.
s e r i e s
potentiometer
HLG-240H-42
HLG-240H-48
HLG-240H-54
42V
48V
54V
21 ~ 42V
24 ~ 48V
27 ~ 54V
5.72A
5A
4.45A
240.24W
240W
240.3W
250mVp-p
250mVp-p
350mVp-p
39 ~ 45V
44.8 ~ 51.2V
50 ~ 57V
2.86 ~ 5.72A
2.5 ~ 5A
2.23 ~ 4.45A
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
93%
93.5%
94%
48 ~ 54V
60 ~ 67V
55 ~ 63V

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HLG-240H-15 and is the answer not in the manual?

Questions and answers

Summary of Contents for Mean Well HLG-240H-15

  • Page 1 B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance. C : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal potentiometer. D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details. SPECIFICATION MODEL...
  • Page 2: Mechanical Specification

    H L G - 2 4 0 H s e r i e s 240W Single Output Switching Power Supply Mechanical Specification Case No.994C Unit:mm Blank:(HLG-240H) 244.2 220.2 300 20 300 20 (Green/Yellow) T case -V(Black) 110.1 AC/L(Brown) +V(Red) AC/N(Blue) SJTW 18AWG 3C SJTW 14AWG 2C 4.2 4PL...
  • Page 3: Block Diagram

    -V(Black) 110.1 AC/L(Brown) +V(Red) AC/N(Blue) SJTW 18AWG 3C SJTW 14AWG 2C 4.2 4PL T case: Max. Case Temperature. IP67 rated. Timer dimming function, contact MEAN WELL for details. Block Diagram Fosc : 100KHz RECTIFIERS EMI FILTER POWER & & SWITCHING...
  • Page 4: Constant Current Mode

    H L G - 2 4 0 H 240W Single Output Switching Power Supply s e r i e s Derating Curve Static Characteristics 230VAC 100VAC (HORIZONTAL) 155 165 INPUT VOLTAGE (V) 60Hz AMBIENT TEMPERATURE ( ) Power Factor Characteristic Constant Current Mode 1 .0 0 0 .9 8...
  • Page 5 A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs. Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode (with LED driver, at area (A) and CC mode (direct drive, at area (B).
  • Page 6 Up to four wires can be connected through this cable joiner by soldering or clamping by tools. LED Lamp HLG-240H O/P Wires CJ04 cable joiner can be purchased independently for user's own assembly. MEAN WELL order No. : CJ04-1, CJ04-2. Junction Box(Option ) 220.2 382.2 (Green/Yellow) -V(Black)

This manual is also suitable for:

Hlg-240h-24Hlg-240h-20Hlg-240h-30Hlg-240h-12Hlg-240h-42Hlg-240h-36 ... Show all

Table of Contents