LNL-1320-S2RP Dual Door Control Module
Note:
Excessive load switching causes contact wear and premature failure. Inductive load (strike)
switching causes EMI (electromagnetic interference) that can interfere with normal operation
of other equipment. To minimize premature contact failure and to increase system reliability,
use a contact protection circuit. Locate the protection circuit as close to the load as possible
(12 inches [30cm] recommended). The circuit's effectiveness decreases if it is located further
away.
Use sufficiently large gauge wire for the load current to avoid voltage loss.
Internal Relay Definitions
Relay Function
Reader 1 - Strike
Reader 1 - Auxiliary
Reader 1 - Shunt
Reader 2 - Strike
Reader 2 - Auxiliary
Reader 2 - Shunt
AC Door Strike Wiring
Suppression MOV selection:
-
Clamp voltage: >1.5x VAC RMS
-
For 24 VAC strike, Panasonic ERZ-C07DK470 typical
124 —
revision 7
Terminal Block
Description
TB2-1
Normally Closed (NC)
TB2-2
Common (C)
TB2-3
Normally Open (NO)
TB2-4
Common (C)
TB2-5
Normally Closed (NC)
TB2-6
Normally Open (NO)
TB2-7
Common (C)
TB2-8
Normally Closed (NC)
TB2-9
Normally Open (NO)
TB4-1
Normally Closed (NC)
TB4-2
Common (C)
TB4-3
Normally Open (NO)
TB4-4
Common (C)
TB4-5
Normally Closed (NC)
TB4-6
Normally Open (NO)
TB4-7
Common (C)
TB4-8
Normally Closed (NC)
TB4-9
Normally Open (NO)