Pipe Blockage Error(Error Code : E422) - Samsung AC071MN4PKH Service Manual

Hide thumbs Also See for AC071MN4PKH:
Table of Contents

Advertisement

4-4-21. Pipe blockage error(Error Code : E422)

1. Test items
1) Check the open state of the outdoor unit service valve.
2) Check the connection of the pipe.
3) Check the operation of the EEV.
4) Check the refrigerant leakage.
5) Check the connection of the indoor unit PBA EVA sensor.
6) Check the fault in the indoor unit EVA sensor.
2. Check procedure
If there occurs E422 error, reset the power
and check in the following order.
Is outdoor unit service valve opened?
Is connection of piping suitable?
(Check the disconnection, bent, or cross-
connection with other sets.)
Does operation error of refrigerant leakage
or EEV appear?
Is it defect of indoor machine EVA sensor
and connection state?
Yes
Yes
Yes
Check whether the pipe is empty and open all
No
the service valves on the gas and liquid pipes..
Modify the piping and connect immediately
No
and then empty the pipes and open the service
Check the replacement of the EEV (body/coil)
No
and the refrigerant leaking part. After that,
Check the temperature value through S-NET,
No
etc. and then if there is a fault, replace and
4-53
Troubleshooting
valves.
recharge.
reconnect.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents