Nokia Customer Care
The CDMA Control dialog box appears.
Figure 11: CDMA Control dialog box for Cell Tx troubleshooting
9. Select the following values:
State = Rho ON
•
Band = Cell
•
Radio Configuration = Mode 1: IS-95 Voice
•
Note: Do NOT select the Set default PDM values option
10. Click Execute.
11. Configure the spectrum analyzer using the following values:
•
Center Frequency = 836.52 MHz
•
Span = 100 MHz
•
Amplitude = 20 dBm
•
Attenuation = Auto
•
BW = Auto
Description/Field
AGC1
AGC2
PA Gain
Rx IF AGC
AFC
Pout
Current
Issue 1 04/2005
Table 2: RF PDM Values
©2005 Nokia Corporation
6235/6235i/6236i (RM-60)
RF Description and Troubleshooting
Reference Value
0
-512
+114
0
0
+16dBm
360mA
Company Confidential
Do NOT select
this option
Page 15