6235/6235i/6236i (RM-60)
RF Description and Troubleshooting
The AMPS Control dialog box appears.
7. Click the Tx Control tab.
8. In the Set Channel field, type 384.
9. In the Power Level field, type 5.
10. Select the Transmitter ON option, and click Execute.
11. Configure the spectrum analyzer using the following values:
•
Center Frequency = 836.52 MHz
•
Span = 100 MHz
•
Amplitude = 20 dBm
•
Attenuation = Auto
•
BW = Auto
Description/Field
AGC1
AGC2
PA Gain
Rx IF AGC
AFC
Pout
Current
Pout w/AAS-10 at Ant. Conn.
Page 12
Figure 8: AMPS Control dialog box
Table 1: RF PDM Values at Power Level 5
©2005 Nokia Corporation
Reference Value
-59
-512
-200
+179
-12
+17dBm
370mA
-8 dBm
Company Confidential
Issue 1 04/2005