FUNCTION LIST

●MONITORING FUNCTIONS and MAIN P ROFILE PARAMETERS
Code
Name
Output frequency monitor
d001
d002
Output current monitor
d003
Motor rotational direction monitor
d004
Process variable (PV), PID feedback monitor
Intelligent input terminal status
d005
d006
Intelligent output terminal status
Scaled output frequency monitor
d007
d012
Torque monitor
d013
Output voltage monitor
d014
Power monitor
Cumulative RUN time monitor
d016
Cumulative power-on time monitor
d017
d080
Trip count monitor
d081
Trip monitor 1 - 6
d086
Warning monitor
d090
F001
Output frequency setting
F002
Acceleration time (1) setting
F202
Acceleration time (1) setting for second motor
Acceleration time (1) setting for third motor
F302
Deceleration time (1) setting
F003
F203
Deceleration time (1) setting for second motor
F303
Deceleration time (1) setting for third motor
F004
Motor rotational direction setting
A Group: Standard functions
A---
b Group: Fine tuning functions
b---
C---
C Group: Intelligent terminal functions
H---
H Group: Motor constants functions
P---
P Group: Expansion card functions
U Group: User-selectable menu functions
U---
●A GROUP: STAND ARD FUNCTIONS
Code
Name
A001
Frequency source setting
Run command source setting
A002
Base frequency setting
A003
Base frequency setting for second motor
A203
Base frequency setting for third motor
A303
Maximum frequency setting
A004
Maximum frequency setting for second motor
A204
Maximum frequency setting for third motor
A304
AT selection
A005
A006
O2 selection
O-L input active range start frequency
A011
O-L input active range end frequency
A012
O-L input active range start voltage
A013
O-L input active range end voltage
A014
O-L input start frequency enable
A015
External frequency filter time constant
A016
A019 Multispeed operation selection
Multispeed frequency setting (0)
A020
Multispeed frequency setting (0) for second motor
A220
Multispeed frequency setting (0) for third motor
A320
A021
I
Multispeed frequency setting (1-15)
A035
Jog frequency setting
A038
Jog stop mode
A039
13
Description
0.00 - 99.99/100.0 - 400.0Hz
0.0 - 999.9A
F(Forward) / o(Stop) / r(Reverse)
0.00 - 99.99/100.0 - 999.9/1000. - 9999./1000 - 9999/ 「 100 - 「999(10,000 - 99,900)
FW
ON
(Example) FW, 7, 2, 1 : ON
OFF
8
7
6
5 4
3
2
1
ON
(Example) 12, 11 : ON
OFF
AL
15 14
13
12
11
0.00 - 99.99/100.0 - 999.9/1000. - 9999./1000 - 3996(10,000 - 39,960)
- 300.-+300.
%
0.0 - 600.0V
0.0 - 999.9kW
0. - 9999./1000 - 9999/ 「 100 - 「999(10,000-99,900)hr
0. - 9999./1000 - 9999/ 「 100 - 「999(10,000-99,900)hr
0. - 9999./1000 - 6553(10,000 - 65,530)
Displays trip event information
Warning code
0.0, Starting frequency to maximum frequency (maximum frequency for second and third motor)
0.01 - 99.99/100.0 - 999.9/1000. - 3600. sec.
0.01 - 99.99/100.0 - 999.9/1000. - 3600. sec.
0.01 - 99.99/100.0 - 999.9/1000. - 3600. sec.
0.01 - 99.99/100.0 - 999.9/1000. - 3600. sec.
0.01 - 99.99/100.0 - 999.9/1000. - 3600. sec.
0.01 - 99.99/100.0 - 999.9/1000. - 3600. sec.
00(Forward)/01(Reverse)
Description
00(Potentiometer) / 01(Terminals) / 02(Operator) / 03(RS485)/
04(Expansion card 1) / 05(Expansion card 2)
01(Terminals) / 02(Operator) / 03(RS-485) / 04(Expansion card 1) / 05(Expansion card 2)
30.Hz-Maximum frequency
30.Hz-Maximum frequency for second motor
30.Hz-Maximum frequency for third motor
30. - 400.Hz
30. - 400.Hz
30. - 400.Hz
00(Selection between O and OI at AT)
/ 01(Selection between O and O2 at AT)
00(Independent)/ 01(Only positive)
/ 02(Both positive and negative)/ 03(Disable) 
0.00 - 400.0Hz
0.00 - 400.0Hz
0. - 100.%
0. - 100.%
00(External frequency output zero reference)/ 01(0Hz)
1. - 30.(Sampling time=2msec.)
00(Binary: up to 16-stage speed at 4 terminals)
/ 01(Bit: up to 8-stage speed at 7 terminals)
0.0, Starting frequency to maximum frequency
0.0, Starting frequency to maximum frequency for second motor
0.0, Starting frequency to maximum frequency for third motor
0.0, Starting frequency to maximum frequency
0.0, Starting frequency to 9.99Hz
00(Free-run stop/disable during RUN)/ 01(Deceleration to
stop/disable during RUN)/ 02(DC braking to stop/disable dur-
ing RUN)/ 03(Free-run stop/enable during RUN)/ 04(Decelera-
tion to stop/enable during RUN)/ 05(DC braking to stop/enable
during RUN)
Default Setting
-FE(CE) -FU(UL)
-
-
-
-
-
-
-
-
-
-
8, 6, 5, 4, 3 : OFF
-
-
AL, 15, 14, 13 :OFF
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.00Hz
0.00Hz
30.00s
30.00s
30.00s
30.00s
30.00s
30.00s
30.00s
30.00s
30.00s
30.00s
30.00s
30.00s
00
00
Default Setting
-FE(CE) -FU(UL)
01
01
01
01
50.
60.
50.
60.
50.
60.
50.
60.
50.
60.
50.
60.
00
00
03
03
0.00
0.00
0.00
0.00
0.
0.
100.
100.
01
01
8.
8.
00
00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
1.00
1.00
00
00
[
= Allowed
]
= Not permitted
×
Run-time
Run-time Data Edit
Setting
(Enabled at b031)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
×
×
[
]
= Allowed
= Not permitted
×
Run-time
Run-time Data Edit