SJ300 Series can be easily operated with the digital operator ( OPE-S ) provided as standard. The digital operator can also
be detached and can be used for remote-control. Multilingual ( English, French, German, Italian , Spanish and Portuguese)
operator with copy function ( SRW-0EX ) and digital operator with potentiometer ( OPE-SR ) are also available as options.
( For US version, OPE-SRE ( English overlay with potentiometer ) is provided as standard. )
Parameter Display
Displays frequency, motor cur-
rent, rotational speed of the
motor, and an alarm code.
Monitor LEDs
Shows drive status.
RUN Key
Press to run the motor.
STOP/RESET Key
Press to stop the drive or
reset an alarm.
Function Key
Press to set or monitor a
parameter value.

1.Setting the maximum output frequency

(1)   or the value previously
  monitored is displayed.
POWER
ALARM
Hz
RUN
V
kW
A
Power
PRG
%
on
機能
記憶
FUNC
STR
(5)
appears.
POWER
ALARM
Hz
RUN
V
kW
A
PRG
%
Press
機能
記憶
FUNC
STR
until
appears.

2.Monitoring output current value

(1)   or the value previously
  monitored is displayed.
POWER
ALARM
Hz
RUN
V
kW
Power
A
PRG
%
on
機能
記憶
FUNC
STR
(2) Function code appears.
POWER
ALARM
Hz
RUN
V
kW
A
PRG
%
Press
key.
FUNC
FUNC
機能
記憶
FUNC
STR
(6) Preset value is displayed.
POWER
ALARM
Hz
RUN
V
kW
A
PRG
%
Press
key.
FUNC
機能
記憶
FUNC
STR
(2) Function code appears.
POWER
ALARM
Hz
RUN
V
kW
A
PRG
%
Press
key.
FUNC
機能
記憶
FUNC
STR
(3)
appears.
RUN
PRG
Press
機能
記憶
FUNC
until
appears.
(7) Newly set value is displayed.
RUN
PRG
Press
  
機能
記憶
FUNC
STR
to set desired value.
(3)   appears.
RUN
PRG
Press
機能
記憶
FUNC
STR
until
appears.
Power LED
Lights when the power input
to the drive is ON.
Display Unit LEDs
Indicates the unit associated
with the parameter display.
Store Key
Press to write the new value
to the EEPROM.
Up/Down Keys
Press up or down to sequence
through parameters and func-
tions shown on the display, and
increment/decrement values.
(4)
is displayed
POWER
ALARM
Hz
RUN
V
kW
A
PRG
%
Press
key.
FUNC
機能
STR
FUNC
(8) Returns to
  the setting is complete.
POWER
ALARM
Hz
RUN
V
kW
A
PRG
%
STR
Press
key
機能
to store the value.
FUNC
*To run the motor, go
back to monitor mode
or basic setting mode.
(4) Output current value
   is displayed.
POWER
ALARM
Hz
RUN
V
kW
A
PRG
%
Press
key.
FUNC
機能
FUNC
POWER
ALARM
Hz
V
kW
A
%
記憶
STR
and
POWER
ALARM
Hz
V
kW
A
%
記憶
STR
POWER
ALARM
Hz
V
kW
A
%
記憶
STR
12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents