Intelligent Terminal Functions - Hitachi SJ300 Series Manual

Sensorless vector contro
Hide thumbs Also See for SJ300 Series:
Table of Contents

Advertisement

Code
Name
b100
Free-setting V/f frequency (1)
Free-setting V/f voltage (1)
b101
Free-setting V/f frequency (2)
b102
b103
Free-setting V/f voltage (2)
b104
Free-setting V/f frequency (3)
b105
Free-setting V/f voltage (3)
Free-setting V/f frequency (4)
b106
Free-setting V/f voltage (4)
b107
b108
Free-setting V/f frequency (5)
b109
Free-setting V/f voltage (5)
b110
Free-setting V/f frequency (6)
Free-setting V/f voltage (6)
b111
Free-setting V/f frequency (7)
b112
b113
Free-setting V/f voltage (7)
b120
Brake control enable
b121
Brake wait time for release
Brake wait time for acceleration
b122
Brake wait time for stopping
b123
b124
Brake wait time for confirmation
b125
Brake release frequency setting
b126
Brake release current setting
●C GROUP: INTELLIGENT TERMINAL FUNCTIONS
Code
Name
C001
Terminal (1) function
C002
Terminal (2) function
C003
Terminal (3) function
C004
Terminal (4) function
C005
Terminal (5) function
C006
Terminal (6) function
C007
Terminal (7) function
C008
Terminal (8) function
C011
Terminal (1) active state
C012
Terminal (2) active state
C013
Terminal (3) active state
C014
Terminal (4) active state
C015
Terminal (5) active state
C016
Terminal (6) active state
C017
Terminal (7) active state
C018
Terminal (8) active state
C019
Terminal FW active state
Terminal (11) function
C021
C022
Terminal (12) function
C023
Terminal (13) function
Terminal (14) function
C024
C025 Terminal (15) function
Alarm relay terminal function
C026
C027
FM signal selection
C028
AM signal selection
C029
AMI signal selection
Description
0.0 - Free-setting V/f frequency (2)
0.0 - 800.0V
0.0 - Free-setting V/f frequency (3)
0.0 - 800.0V
0.0 - Free-setting V/f frequency (4)
0.0 - 800.0V
0.0 - Free-setting V/f frequency (5)
0.0 - 800.0V
0.0 - Free-setting V/f frequency (6)
0.0 - 800.0V
0.0 - Free-setting V/f frequency (7)
0.0 - 800.0V
0. - 400.Hz
0.0 - 800.0V
00(Disable) / 01(Enable)
0.00 - 5.00sec.
0.00 - 5.00sec.
0.00 - 5.00sec.
0.00 - 5.00sec.
0.00 - 99.99/100.0 - 400.0Hz
0.00
rated current to 2.00
rated current
×
×
Description
01(RV:Reverse) / 02(CF1:Multipeed(1)) / 03(CF2:Multispeed(2)) / 04(CF3:Multi-
speed(3)) / 05(CF4:Multispeed(4)) / 06(JG:Jogging) / 07(DB:External DC braking) /
08(SET:Second motor constants setting) / 09(2CH:Second accel./decel.) /
11(FRS:Free-run stop) / 12(EXT:External trip) / 13(USP:Unattended start protection) /
14(CS:Change to/from commercial power supply) / 15(SFT:Software lock) /
16(AT:Analog input selection) / 17(SET3:Third motor constants setting) /
18(RS:Reset) / 20(STA:3-wire start) / 21(STP:3-wire stop) / 22(F/R:3-wire fwd./
rev.) / 23(PID:PID On/Off) / 24(PIDC:PID reset) / 26(CAS:Control gain setting) /
27(UP:Remote-controlled accel.) / 28(DWN:Remote-controlled decel.) /
29(UDC:Remote-controlled data clearing) / 31(OPE:Operator control) /
32(SF1:Multispeed bit command(1) / 33(SF2:Multispeed bit command(2) /
34(SF3:Multispeed bit command(3) / 35(SF4:Multispeed bit command(4) /
36(SF5:Multispeed bit command(5) / 37(SF6:Multispeed bit command(6) /
38(SF7:Multispeed bit command(7) / 39(OLR:Overload limit change) /
40(TL:Torque limit enable) / 41(TRQ1:Torque limit selection(1)) /
42(TRQ2:Torque limit selection(2)) / 43(PPI:P/PI selection) / 44(BOK:Brake
confirmation signal) / 45(ORT:Orientation) / 46(LAC: LAD cancel) /
47(PCLR:Positioning deviation reset) / 48(STAT:90-degree pulse-train input phase
difference permission) / 255 (NO:Not selected)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(RUN:Run signal)/ 01(FA1:Frequency arrival signal (at the set frequency))/
02(FA2:Frequency arrival signal (at or above the set frequency))/ 03(OL:Overload
advance notice signal)/ 04(OD:Output deviation for PID control)/ 05(AL:Alarm sign-
al)/ 06(FA3:Frequency arrival signal (only at the set frequency))/ 07(OTQ:Over-
torque) / 08(IP:Instantaneous power failure signal)/ 09(UV:Under-voltage signal)/
10(TRQ:In torque limit)/ 11(RNT:RUN time over)/ 12(ONT:Power-on time over)/
13(THM:Thermal alarm)/ 19(BRK:Brake release)/ 20(BER:Brake error)/ 21(ZS:Zero
speed)
22(DSE:Speed deviation excessive) / 23(POK:Positioning completion)
24(FA4:Frequency arrival signal (at or above the set frequency)(2))/ 25(FA5:Fre-
quency arrival signal (only at the set frequency)(2))/ 26(OL2:Overload advance
notice signal(2))
(Terminal 11 - 13 or 11 - 14 are automatically configured as AC0 - AC2 or AC0 - AC3
per alarm code output selection)
00(Output frequency) / 01(Output current) / 02(Output torque) /
03(Digital output frequency-only at C027) / 04(Output voltage)
/ 05(Power) / 06(Thermal load ratio) / 07(LAD frequency)
[
= Allowed
= Not permitted
×
Default Setting
Run-time
Run-time Data Edit
Setting
(Enabled at b031)
-FE(CE) -FU(UL)
0.
0.
×
×
0.0
0.0
×
×
0.
0.
×
×
0.0
0.0
×
×
0.
0.
×
×
0.0
0.0
×
×
0.
0.
×
×
0.0
0.0
×
×
0.
0.
×
×
0.0
0.0
×
×
0.
0.
×
×
0.0
0.0
×
×
0.
0.
×
×
0.0
0.0
×
×
00
00
×
0.00
0.00
×
0.00
0.00
×
0.00
0.00
×
0.00
0.00
×
0.00
0.00
×
×
Rated current
Rated current
[
= Allowed
= Not permitted
×
Default Setting
Run-time
Run-time Data Edit
Setting
(Enabled at b031)
-FE(CE) -FU(UL)
18
18
×
(RS)
(RS)
16
16
×
(AT)
(AT)
06
06
×
(JG)
(JG)
11
11
×
(FRS)
(FRS)
09
09
×
(2CH)
(2CH)
03
13
×
(CF2)
(USP)
02
02
×
(CF1)
(CF1)
01
01
×
(RV)
(RV)
00
00
×
00
00
×
00
00
×
00
00
×
00
00
×
00
01
×
00
00
×
00
00
×
00
00
×
01
01
×
(FA1)
(FA1)
00
00
×
(RUN)
(RUN)
03
03
×
(OL)
(OL)
07
07
×
(OTQ)
(OTQ)
08
08
×
(IP)
(IP)
05
05
×
(AL)
(AL)
×
00
00
×
00
00
00
00
×
]
]
16