Specifications - Siemens AS 100 Instruction Manual

Table of Contents

Advertisement

Specifications

Model
• standard
• extended
Power
• 20 to 30 V DC
• 18 mA typical
Operating Temperature
1
• standard
• extended:
Relative Sensitivity
• 0.5% / °C of reading, average over the operating range
Output
• analog, 0.08 to 10 V DC nominal, 100 KΩ minimum load impedance
Construction
• housing
• cable
1.
Class II and ATEX II versions available
2.
Class II version available
Page 2
standard operating temperature range (see below)
extended operating temperature range (see below)
-20 to 80 °C (-4 to 176 °F)
-30 to 120 °C (-22 to 248 °F)
-40 to 125 °C (-40 to 257 °F)
304 stainless steel
303 stainless steel (hazardous rated version)
standard: 4 m (13 ft) cable, PVC jacketed, 3 twisted pairs, 24 AWG,
shielded
extended: 4 m (13 ft) cable, thermoplastic elastomer jacketed, 6
conductor, 24 AWG conductor, shielded
SITRANS AS 100 – INSTRUCTION MANUAL
2
or
7ML19985DM02