Mode Selecfor
Temp dial
Allows you to choose between Room Temp Mode,
Mows you to adjust the mom temperature in Room Temp
Stove Temp Mode, or OFF. Also allows you to vary
Mode using
the
outer scale marked in degrees Fahrenheit.
the distribution blower speed by turning the knob
It also allows you to aqustthe stove temperature while in
to the high or low side of each mode.
I
Stove Tern0
Mode
usina the
inner scale marked from 1 to
Distribution Blower
speed
adjustment
although as the stove
Indicates igniter is on.
temp. goes up, so does
the
L
and H scale.
Indicates power to the
feed motor.
lndicates power to
combustion blower
Test
lndicates power to
distribution blower.
Runs all motors at full
speed tbr one mhute to
status
Light
check operation. After
COMBUSTION
Will be lit in either stove
two minutes the stove
or mom temp mode when
pointer is not within off
and the blowers
position band except after
-
normal shut down. Blinks
to indicate errors listed
remind you that you are
bebw.
PowerLight
lndicates power to the
control.
feed fate
1 Blink: lndicates control board self diagnostic fail-
ure. This requires a manual reset*.
2 Blinks: lndicates that the feeder position switch
jumper (J2) on the rear of the control board is not
connected. The stove will function normally until shut
down is attempted. The stove will not shut down
until it runs out of fuel and cools to a safe tempera-
ture.
3 Blinks: lndicates ESP (Exhaust Sensing Probe)
failure. This requires a manual reset*.
4 Blinks: Can occur only in Room Temp Mode and
indicates Room Sensing Probe failed or not in-
stalled. If a Room Sensing Probe is then installed,
the status light will automatically reset.
NOTE: Unit will not start in "AUTO" with this status
error.
5 Blinks (In Igniter Auto.
Mode
Only): lndicates
that the unit has failed to light within the 36 minute
start cycle. To reset
-
Turn Mode Selector to "OFF",
then turn to either mode again.)
6 Blinks
:
lndicates that the control has calculated
poor or incomplete combustion occuning for more
than 50 minutes. See Troubleshooting section for
more details.
*
Manual reset- disconnect power cord for a few
seconds and reconnect. If error still occurs call your
Dealer.