Accentra Motor & Component Locations
Cor
Outside Air Ir
4
1
Low Draft
Pressure
Switch
/
/
Distribution Blower
Probe
3" Flue Pipe Connector
The Combustion Motor Fuse is a thermal overload
one-time fuse link within the motor windings. Should the distri-
bution motor fail with the unit operating over
80%,
this fuse will
protect the other components by melting off at a set tempera-
ture. With the fuse blown, the combustion motor will stop.ln
turn, the feeder motor will not operate and the stove will go out.
This may only happen when the unit is on Maximum (#7 on the
Temperature Dial,
# 6
on the Feed Adjuster and Distribution blower
not operating). If this fuse does blow, the unit will need service.
Accentra Pellet Stove Safety Devices
The
C o n t r o l
combination is responsible for
The Low Dratt Pressure Switch is a differential pres-
all high limit safety control. There are 2 high limits, one normal
sure switch that senses the pressure between the firebox
operation high limit and one backup high limit. The control has
and the room. If the pressure becomes too low for proper
an automatic diagnostic circuit that continuously monitors the
combustion, the switch opens, turning off the feeder motor
ESP and Room Sensor for faults. If a fault should occur, the
and the igniter element. This switch is connected into the AC
control sends a status alert and at the same time the unit goes
(high voltage) wires; therefore, the control may show the feeder
down to minimum feedlminimum burn as a safety condition.
motor and igniter lights "on" but they are not.