Download Print this page

Harman Stove Company Accentra-2 Installation And Operating Manual page 5

Hide thumbs Also See for Accentra-2:

Advertisement

Ignitor Switch t o " A U T 0 (down position)
Make sure the unit is plugged into a 120 VAC,
60 HZ electrical source. The power light should
be the only light lit.
Fig. 3
See Note 7.
1. Turn Mode Selector to "OFF".
2. Fill hopperwith pellets.'
3. Clean burn pot with scraper, if necessary5
4. If starting after an empty hopper, turn Feed
Adjuster to "TEST" (for one 60 second c y ~ l e ) . ~
This will purge pellets into the auger tube and also
allow you to check the motors for operation. NOTE:
The auger motor will not operate with the view
door or ash pan door open.3
1. Fines are smallpieces of broken pellets (sawdust). Fines do
not flow easily and offen build up on the hopper funnel bottom
5. Turn Feed Adjuster to #4.4
angles. These fines can be pushed into the feeder opening
6 Flip the Ignitor Switch down into the "AUTOH
and then fill the hopper with pellets. As the system works, they
will be burned.
position.
2. The "TEST" cycle will operate the feeder motor for exactly
one minute. Turning to "TEST" again and again may purge too
7. Turn the Temperature Dial to desired room
much fuel into the burn pot causing excessive smoke on start-
UR.
temperature.
3. The firebox lowpressure switch ~ i l l n ~ t
allowthe augermotor
8. Turn Mode Selector to Room Temperature or
or the ianiter element to o~erate if the view door is ooen.
4. ~ d j u s t Feed Rate. If this is your first fire or you are trying
Stove Temperature.
different pellets, set the feed adjuster to
#4,
Fig. 3. This is a
conservative number and will ~robablv need to be increased.
9. Fill hopper with pellets and remove ashes as
Affer you know a feed rate setting that works well, use that
setting. Remember, if your feed rate is too high you may waste
req~ired.~
fuel.
5. This is usually a weekly maintence procedure. Cleaning the
burn pot with the scraper with a small amount of new fuel in the
bottom is not a problem. First, scrape the ashes on the front of
the burn pot into the ash pan. Then scrape the holed surface
downward into the burn pot. When the stove is ignited these
scrapings will be pushed out by the feeder.
6. The ash pan can hold the ashes from approximately 1 ton of
premium fuel. This means the ashes will only need to be
emptied a few times a year.
7. Setting the feed adjuster
# for maximum burn: With the unit
burning in ''AUTO'', turn to "Stove Mode" and put the fan on
"H':
Set the Temperature Dial to #7. Allow the unit to burn for about
30 minutes and check ash on front of burn pot. Fig. 4. If the ash
line is larger than 1 ", turn the feed adjuster from #4 to #5. Allow
another 30 minutes of burn time and check again. I f , at
#6
setting, a
7"
orless ash bed is not obtainable, it is not a problem.
The 1" ash bed is only a maximum burn rate and at most
normal settings the ash bed w~ll be larger.
Notice when using Optional Battery Back-Up:
If
a power outage is expected, change the toggle
switch to Manual Mode. The Harman 502H Battery
Backup is incapable of powering the igniter. If an
automatic ignition is attempted while the stoves is
being powered by the battery back up, it may cause
damage to both the stove and the battery backup
unit.
Warning
NEVER USE GASOLINE, GASOLINE-TYPE LANTERN
FUEL, KEROSENE, CHARCOAL LIGHTER FLUID,
OR SIMILAR LIQUIDS TO START OR 'FRESHEN UP'
A FIRE IN THIS HEATER. KEEP ALLSUCH LIQUIDS
WELL AWAY FROM THE HEATER WHILE IN USE.

Advertisement

loading