PHYSICAL
BASIC UNIT
Length overall
Width
Height overall
Weight
FOUR-WHEEL TRAILER-MOUNTED UNIT
Length overall
Width
Height
Weight
FIFTH-WHEEL TRAILER MOUNTED UNIT
Length overall, with tongue up
Length overall, with tongue down
Width
Height
Weight (with 1/4 tank of fuel
and no cables)
GENERATOR
Output power rating
Output voltage
Rated load capacity
Frequency (cycles-per-second)
Output kilowatts
Power factor
Duty cycle
Operating speed at 400 Hz
Overload capacity
(125% of rated load capacity)
GENERATOR PROTECTIVE SYSTEM
Overvoltage relay
Undervoltage relay
Overfrequency relay
Underfrequency relay
Overload relay
Undervoltage time delay relay
1-1
Page 4
109.6 inches (2784 mm)
45.5 inches (1156 mm)
62.0 inches (1575 mm)
3500 pounds (1496.8 kg)
119.0 inches (3023 mm)
80.0 inches (2032 mm)
79.0 inches (2007mm)
5400 pounds (2358.7 kg)
160 inches (4064 mm)
228 inches (5791 mm)
84 inches (2134 mm)
84 inches (2134 mm)
7160 pounds (3247 kg)
140 KVA
115/200 V
404 Amp
400 Hz
112 KW
0.8 PF
100%
1714 RPM
505 Amp
trips 130 V to 134 V; resets 125 V
trips 102 V or below; resets 110 V
trips 415 Hz to 425 Hz; resets 410 Hz
trips 375 Hz to 385 Hz; resets 385 Hz
trips 175 KVA in less than 5 minutes
4 to 12 seconds