DISASSEMBLY INSTRUCTIONS SIZE 36

No.
Part name
1
Panel plate
Procedures
How to remove the panel
plate.
1) Stop the air conditioner
and turn off the power
breaker.
2) Remove the big handle
first, then remove the top
cover (7 screws).
3) Remove the front panel
screws (11 screws).
(4) Remove the right side
panel screws (13).
Remarks
Screws of top panel(3screws,1screws is under the big handle)
\
Screws of front panel (11 screws)
2
3
38
4 screws of big handle
Screws of big
handle
(3 screws)
4