SPECIFICATIONS − OUTDOOR
Size
System
Outdoor Model
Voltage, Phase, Cycle
Electrical
MCA
MOCP - Fuse Rating
Cooling Outdoor DB Min - Max
Operating Range
Heating Outdoor DB Min - Max
Total Piping Length
*
Piping Lift
Piping
Pipe Connection Size - Liquid
Pipe Connection Size - Suction
Type
Refrigerant
Charge
Metering Device
Face Area
No. Rows
Outdoor Coil
Fins per inch
Circuits
Type
Model
Compressor
Oil Type
Oil Charge
Rated Current
Unit Width
Unit Height
Unit Depth
Outdoor
Net Weight
Airflow
Sound Pressure
* Condensing unit above or below indoor unit
Table 2—Outdoor
HEAT PUMP
38MBRQ36A-- 3
V/Ph/Hz
A.
A.
° F (° C)
-4~ 122 (-20~ 50)
° F (° C)
-22~ 86 (-30~ 30)
ft (m)
ft (m)
in (mm)
in (mm)
lbs (kg)
Sq. Ft.
ATF310D43UMT
ESTER OIL VG74
Fl. Oz.
RLA
in (mm)
in (mm)
in (mm)
lbs (kg)
CFM
dB(A)
3
36
38MBRQ48A-- 3
208/230-1-60
208/230-1-60
30
50
-4~ 122 (-20~ 50)
-22~ 86 (-30~ 30)
213 (65)
98 (30)
3/8 (9.52)
3/8 (9.52)
5/8 (16)
R410A
6.72 (3.05)
9.26 (4.2)
EEV
8.0
2
18
4
Rotary Inverter
Rotary Inverter
ATQ420D1UMU
ESTER OIL VG74
28.2
8.9
40.63 (1032)
40.63 (1032)
31.89 (810)
52.48 (1333)
17.91 (544)
17.64 (448)
136.47 (61.9)
217.4 (98.6)
2,130
63.0
48
35
50
213 (65)
98 (30)
5/8 (16)
R410A
EEV
13.6
2
18
8
39.5
11.9
4,500
62.5

Hide quick links: