Installation Diagram Of Indoor And Outdoor Units; Optional Installation Parts - Carrier 42GCVPH010-303P Installation Manual

Table of Contents

Advertisement

INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS

INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
5
Flat head
7
wood screw
Remote control
4
holder
Wireless
2
remote control

Optional Installation Parts

Part
Parts name
code
Refrigerant piping
Liquid side : Ø6.35 mm
Gas side
: Ø9.52 mm
A
(42GCVPH010, 013-303P)
: Ø12.70 mm
(42GCVPH018-303P)
Pipe insulating material
(polyethylene foam, 6 mm thick)
For 42GCVPH010, 013-303P
B
(polyethylene foam, 8 mm thick)
For 42GCVPH018-303P
Putty, PVC tapes
C
Hook
Mounting
6
screw
Hook
Filter
Batteries
3
Hook
Installation
1
plate
Vinyl tape
Apply after carrying
out a drainage test.
Saddle
Extension drain hose
(Not available,
provided by installer)
Fixing bolt arrangement of outdoor unit
Q'ty
• Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be
exposed to a strong wind.
• Use Ø8 mm or Ø10 mm anchor bolts and nuts.
One
each
1
One
each
6
For the rear left and bottom left piping
Cut out a piece of SPACER from indoor
unit packaging box, roll it and insert
between the indoor unit and wall to tilt
the indoor unit for better operation.
The auxiliary piping can be connected
to rear left, rear right, bottom right or
bottom left.
Shield pipe
Rear right
Do not allow the drain hose to get slack.
Make sure to run the drain hose sloped
downward.
The flare connection should be installed
outdoors.
Refrigerant piping must be protected
from physical damage.
Install a plastic cover or equivalent.
Insulate the refrigerant pipes separately
with insulation, not together.
6 mm or 8 mm thick heat
resisting polyethylene foam
108 mm
125 mm
Air inlet
Air outlet
600 mm
Wall
Bottom
Rear
right
left
Bottom left
Cut the piping
hole sloped
slightly.
90 mm
Drain outlet