Gph1648H41 - Goodman *PH 16 Service Instructions Manual

Table of Contents

Advertisement

WIRING DIAGRAMS
YL/PK
BK
PU
BL
GR
C
L G N
1
2 3
SEE NOTE 2
L1
C
SEE NOTE 2
L
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
LPS
BL
CNT
CCR
0
0
LVDR
0-RV
C-RV
W
Y
HVDR
Y
H
PS2
RCCF
YL
CONTROL
BOX
GR
4 5
DFT
EM
RVC
SUPPLY VOLTAGE
208-230/1/60
T2
C
R
T1
C
COMP
C
DF1
DF2
S
H
RCCF
HVDR
F
S.A.
CM
SEE NOTE 6
SEE NOTE 4
CHS
CH
N
EM
G
208-230
SEE NOTE 3
2
1
3
TR
++
SEE NOTE 3
PU
BK
PU
1
2
3
208
C
240
TR
RD
24V
BL
RD
GR
RD
RD
BR
BL
PLF
3
6
9
C
F
2
5
8
BR
RD
4
7
1
BR
PU
BK
SA
SEE NOTE 4
BR
BK
PU
YL
CM
HPS
COMPONENT LEGEND
C
CONTACTOR
CCR
COMPRESSOR CONTACTOR RELAY
CH
CRACKCASE HEATER
L2
CHS
CRACKCASE HEATER SWITCH
CM
CONDENSER MOTOR
COMP
COMPRESSOR
DC
DEFROST CONTROL
DFT
DEFROST THERMOSTAT
EM
EVAPORATOR MOTOR
GND
EQUIPMENT GROUND
HVDR
HIGH VOLTAGE DEFROST RELAY
LPS
LOW PRESSURE SWITCH
LVDR
LOW VOLTAGE DEFROST RELAY
LVJB
LOW VOLTAGE JUNCTION BOX
PLF
FEMALE PLUG / CONNECTOR
RVC
REVERSING VALVE COIL
RCCF
RUN CAPACITOR FOR
COMPRESSOR AND FAN
SA
START ASSIST
TR
TRANSFORMER
HPS
HIGH PRESSURE SWITCH
CSR
COMPRESSOR SOLENOID RELAY
SOL
HI STAGE SOLENOID
JUNCTION
TERMINAL
INTERNAL TO
INTEGRATED CONTROL
PLUG CONNECTION
IGNITER
SWITCH (PRESS.)
OVERCURRENT
PROT. DEVICE
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS
ORIGINAL (AT LEAST 105 C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE YELLOW AND WHITE
LEADS FROM EM"2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE
ENERGIZED, THE HIGHER SPEED SETTING IS USED.
3 FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
4. START ASSIST FACTORY EQUIPPED WHEN REQUIRED
5. USE COPPER CONDUCTORS ONLY
++
USE N.E.C. CLASS 2 WIRE
6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY
EQUIPPED WHEN REQUIRED.
7. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTACTOR
COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONFIGURATION.
8. COMMON SIDE OF CONTACTOR CAN NOT BE GROUNDED OR
CONNECTED TO ANY OTHER COMMON (24V).
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION

GPH1648H41**

SEE
3
2
NOTE 8
4
1
SEE
NOTE 7
BK
BL
PU
T2
L2
RD
C
SEE NOTE 5
BK
L1
T1
BK
PU
GND
OR
RD
LVJB
GR
PU
RD
GR
WH
OR
BR
BL
RD
BK
S
C R
COMP
SEE NOTE 6
FACTORY WIRING
BK
BL
BR
GR
OR
PU
RD
WH
YL
EQUIPMENT GROUND
FIELD GROUND
FIELD SPLICE
SWITCH (TEMP)
2
0
8
-
2
3
0
/
1
/
60
T
H
Y1
E
R
R
G
M
W1
O
O
S
W2
T
C
A
++
T
SEE NOTE 6
LINE VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH
VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
WIRE CODE
BLACK
BLUE
BROWN
GREEN
ORANGE
PURPLE
RED
WHITE
YELLOW
0140G03658-A
49