P10: Tool offset
A tool offset can be defined here.
Range: 000000.1 ... 999999.9
P11: Saw blade
The saw blade thickness can be entered here.
Range: 0000.1 ... 9999.9
P16: Default Initialization
Parameters are reset to default values. (0: not init., 1: default init.)
Enter „1" and confirm by pressing the „Incr/Abs" key.
After power off and on again the device has been reset to its default values.
P17: Function of external Input 1
The external input 1 can be programmed as follows:
0 = The input has no function
1 = The input will set the actual value to the defined reference value (P09)
2 = The input will reset the actual value to zero
P18: Function of external Input 2
The external input 2 can be programmed as follows:
0 = The input has no function
1 = The input will add the tool offset (P10) only if P19=0
P19: Trigger for external input 1
0 = Level-sensitive (high)
1 = Edge-sensitive (positive)
P20: Display-Mode
0 = Standard
1 = Rotation speed
3 = Angle
P99: Software version
This parameter displays the software version
*) The device must be turned off and on again