6.3

Key Functions

The operation of the device is divided into 2 levels:
Parameter level: For configuration of the main operating parameters ( 7).
User level: Allows access to the basic functions of the unit (depends on software version).
All entries and settings are made exclusively via the 4 front keys or various key combinations.
Regular mode:
Incr /
Abs
+
F
+
F
+
Incr /
F
Abs
Parameter level:
Incr /
Abs
F
+
Incr /
F
Abs
Press shortly = switching from absolute to incremental measuring
Press shortly = activate tool offsets. (in the absolute mode)
An activated tool offsets are indicated by the digit „1", shown
in the upper display frame.
Press shortly = set to reference value (in the absolute mode)
Press for 3 seconds = change reference value
Switching back to normal mode: Incr/Abs key
Press shortly = set to „0"(in the absolute mode)
Press for 3 seconds = change tool offset
Switching back to normal mode: Incr/Abs key
Press for 3 seconds = entering the parameter level
Press shortly = select decade
Press shortly = increase decade
Press shortly = save changes and switch over to next parameter
Input of negative parameters
(negative sign only possible for a value unequal 0)
Press for 3 seconds = quit the parameter level