7 Parameter Level

This section describes the available parameters and their settings. A parameter list for a quick overview of all
available parameters can be found in the next chapter ( 8). Specific customer settings can be added there.
P01: Counting direction
Up / down switchover (0: forwards, 1: backwards)
P02: Display mode (measurement unit)
Select the desired measurement unit for the display:
0 = mm
1 = inch
2 = m
3 = °
4 = RPM
5 = no measurement unit
P03: Decimal place
To define a decimal place (0 = 1 / 1 = 0.1 / 2 = 0.01 / 3 = 0.001).
P05: Keyboard lock
0 = off
1 = on
P06: Edge evaluation
Settings of edge evaluation can be chosen.
Range: Evaluation of 1 / 2 / 4 edges (0: x 1, 1: x 2, 2: x 4)
P07: Encoder system*
To select the measuring system
0 = Incremental (rotary encoder, LMIX, EMIX, PMIX)
1 = Absolute (EMAX)
2 = Reserved
3 = Reserved
P08: Multiplication factor
A multiplication factor can be defined here.
Range: 00.00001 ... 99.99999
P09: Reference value
A reference value can be entered here.
Range: 000000.1 ... 999999.9
*) The device must be turned off and on again