AMBIENT CONDITIONS

1. This unit is designed for operation in a room ambient of
never be used outside or located in direct sunlight.
Randell has attempted to preset the temperature control to ensure that your unit runs at an optimum
temperature, but due to varying ambient conditions, including elevation, food type and your type of
operation, you may need to alter this temperature.
Figure 1

Before making temperature adjustments:

A.
Allow adequate time for the cabinet temperature to equalize. When initially started or when
first loaded, it can take a long time for temperatures in the display area to stabilize.
B.
Make sure that unit operation is not being effected by room ambient conditions. (See Ambient
Conditions section above). If there are any significant ambient issues, adjusting the temperature
setting may not help.
To raise temperature:
A.
Push and hold the "SET" button until set point 33 appears then release the "SET" button.
33 is the current set point temperature.
B.
Push and release the up arrow 1 or more times until the desired temperature is displayed.
Push and release the "SET" button one time. The new set point will flash 3 times and then
will be locked in.
To lower temperature:
A.
Push and hold the "SET" button until 33 appears and then release the "SET" button. 33 is
the current set point temperature.
B.
Push and release the up arrow 1 or more times until the desired temperature is displayed.
Push and release the "SET" button one time. The new set point will flash 3 times and then
will be locked in.
NOTE: The FX-1 (2N1) Series Unit is designed to operate in both refrigerated or freezer
mode by adjusting the "SET" point to the desired temperature. The maximum highest
setting is 40° F and the minimum lowest setting is -5° F. If the settings need to go above or
below this point there may be other contributing factors as to the cause of the
temperature variances, please contact the factory at 1-800-621-8560.
16
16
16
16
Your FX-1 (2N1) Series Unit is equipped with an
electronic temperature control. Figure 1, left, illustrates
the Dixell XR60C control location on the front above the
louvered panel.
Figure 2, left, illustrates an alternate electronic
temperature control, Dixell XR60CX with blue LED.