Control Key Descriptions; How To Set The Real Time Clock (Rtc) - Randell FX-1 Operator's Manual

Fx series cooling systems
Hide thumbs Also See for FX-1:
Table of Contents

Advertisement

1 – UP/TEMP/
MANUAL
DEFROST
5 – DOWN/
TEMP/ CLOCK

CONTROL KEY DESCRIPTIONS

1.
UP/TEMP/MANUAL DEFROST – used to browse menu, raise temperature settings and activate
manual defrost.
2.
START/STOP cycle – used to start and stop current cycle monitored by the yellow LED upper left
corner of button.
3.
CYCLE selection – used to browse cycles 1 through 4 monitored by the yellow LED upper left
corner of button.
4.
LIGHT button – used to switch the light on and off (this button is not used in model FX1-4N1).
5.
DOWN/TEMP/CLOCK – used to browse menu, lower temperature settings and set real time clock
6.
SET – used to change the set points in any cycle monitored by the yellow LED upper left corner
of button.
7.
PRINTER – used to enable/disable the printer if printer is provided monitored by the yellow LED
upper left corner of button.
8.
AUX – used to switch auxiliary functions on and off monitored by the yellow LED upper left
corner of button.

HOW TO SET THE REAL TIME CLOCK (RTC)

Press and hold the DOWN
Use the UP and DOWN key
n
n
= minutes
I
H o u
= hours
y
d A
= date day
n
o n
= date month
y
E A
= date year
n
t
= USA or
I
Europe (EU) time
key until the nIn label (minutes) is displayed.
or
to browse the parameters.
TO MODIFY: Press the SET
keys.
TO CONFIRM: Press the SET
TO EXIT THE RTC MENU: Press together the SET
wait 5 seconds.
FX1- 4N1 Control Operation con't
key and then the UP
key.
FIGURE-D
and DOWN
+
UP keys or
randellfx.com
23
23
23
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx1-4n1Fx1-2n1Fx series