DP7500/A GENERATOR INSTALLATION AND OPERATORS MANUAL WINCO INC. 225 S. CORDOVA AVE. LE CENTER, MN 56057 507-357-6821 SERVICE DEPT. 507-357-6831 www.wincogen.com...
Should you experience a problem please follow the “Troubleshooting GENERATOR CONNECTIONS Tables” near the end of this manual. The warranty listed in the manual STARTING ELECTRIC MOTORS describes what you can expect from WINCO should you need service PREPARING THE UNIT assistance in the future. UNPACKING...
CAUTION indicates a potentially hazardous situation which, if not GENERATOR avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. Model DP7500/A 1. ELECTRICAL SHOCK - Starting Watts 7,500 Running Watts 6,720...
PLEASE NOTE There are 3rd party companies making enclosures for 5. CLEANLINESS - generators that have been properly engineered. The use of these 3rd Keep the generator and surrounding area clean. party enclosures is acceptable as long as they have been certified and meet current code.
Honda engine uses an float switch mounted inside the engine. If the let WINCO take care of the freight claim. If you sign for the unit, the oil level drops below a certain point the low oil module on the engine will shut it down.
LIFTING EYE INSTALLATION The use of fuel additives, such as Sta-Bil, or an equivalent will minimize the formation of fuel gum deposits. If a unit has been out of operation for an extended period of time, it is best to drain old fuel from the The lifting eye is shipped loose along with a bag of parts.
STARTING HINTS 4. Operate the starter. Pull the starter grip lightly until you feel resistance, then pull briskly in the direction of the arrow as shown below. Return the starter grip gently. 1. COLD WEATHER A. Use the proper oil for the temperature expected. B.
CAUTION: EQUIPMENT OVERLOAD slight decrease in speed, together with the voltage drop within the generator itself, results in a slightly lower voltage when the generator Keep the generator load within in the generator and receptacle is loaded to its full capacity than when running no load. The slight nameplate rating.
1. These engine-generator sets are designed for portable heavy duty commercial use. Receptacles are provided on the control panel to permit 120 and 240 Volt portable appliances and tools to be plugged directly into them. A 4-wire receptacle (two hot, one ground, and one neutral) has been provided on the control panel for use in temporary power applications requiring 120/240 Volt power.
The Oil Alert system will automatically stop the engine before the 3. Place the O-Ring in the fuel valve and install the sediment cup. oil level falls below the safe limit. Tighten the sediment cup securely. 4. Move the fuel valve to the ON position, and check for leaks. CAUTION: EQUIPMENT DAMAGE: Replace the O-Ring if there is any leakage.
TROUBLESHOOTING 1. Keep the air inlet screen on both the engine and generator free of any dirt or debris to ensure proper cooling. At least yearly, remove the blower housing on the engine and clean the chaff and dirt out of Problem Possible Causes the engine cooling fins and fly wheel.
WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. WINCO is liable for the repair or replacement of the product only and is not liable for incidental or consequential damages as permitted by your state. This warranty gives you specific legal rights which may vary from state to state.