2.
Figure 8
3.
Figure 9
Fig. 9a
Re-engage spring loaded spur gear by turning Disengage Shaft (2) in Figure 8.
Disengage Shaft (2) will rise.
Geared Rotary Limit Switch Setting Instructions
Section 4: Geared Rotary Limit Switch Setting Instructions
Disengage spring loaded spur gear — Push Disengage Shaft (2) in Fig. 8 down, then
rotate 90° so that shaft is captured in down position. This disengages limit switch
gears from the spring loaded gear pinion assembly.
(2)
Line up LSO indicator: If switch rotor does not line with arrows on instruction plate as
shown in fig. 9, rotate screwdriver in same direction noted in Step 1 until switch just
rotates. If indicators line up as shown in fig. 9a, rotate screwdriver in the opposite
direction until switch just rotates, then slowly reverse direction to match fig. 9a.