JVC HX-Z9 Service Manual page 35

Compact component system
Hide thumbs Also See for HX-Z9:
Table of Contents

Advertisement

4.4
Mechanism section
Item
Condition
Head azimuth
Test tape
:VT703L (8kHz)
Output terminal
:Speaker out
Tape speed
Test tap
:VT712 (3kHz)
Output terminal
:Speaker out or
Headphone out
Item
Condition
Tape speed
Test tape
diviation at
: VT712 (3kHz)
FWD/REV
Output terminal
:Speaker out or
Headphone out
Wow & Flutter
Test tape
: VT712 (3kHz)
Output terminal
:Speaker out or
Headphone out
Measurement method
(1) Playback the test tape VT703L (8kHz).
(2) Adjust to maximum output level by azimuth ad-
justment screw for forward side and reverse
side.
(3) This adjustment is adjust by adjustment screw
of forward side and adjustment screw of re-
verse side.
Playback the test tape VT712 (3kHz) at end of
forward side,adjust to 2,940~3,90Hz indication of
frequency counter by VR37.
Measurement method
Playback the test tape VT712 (3kHz) at end of
forward and reverse, tape speed deviation should be
less than 6.0Hz.
Playback the test tape VT712 (3kHz) at start of
forward and reverse, Wow & Flutter are should be
less than 0.25%(WRMS).
Adjustment
Ref. value
position
Maximum output Only adjust at
changed head
2,940 ~ 3,090Hz VR37
Adjustment
Ref. value
position
Leass than
VR31
6.0Hz
Less than 0.25%
(WRMS)
(No.22066)1-35