Table of Contents

Advertisement

Quick Links

UltraTEV Plus
Operating Manual
2
Product Code: UTP2
Version: 5
Date: October 2016

Advertisement

Table of Contents
loading

Summary of Contents for EA Technology UltraTEV Plus2

  • Page 1 UltraTEV Plus Operating Manual Product Code: UTP2 Version: 5 Date: October 2016...
  • Page 2: Table Of Contents

    EA Technology UltraTEV Plus Operating Manual 2388L015 Contents FCC Warning Statement ................................1 IC Warning Statement ................................1 What does the UltraTEV Plus² do? ........................2 What’s in the Box? ................................ 3 Important Information .............................. 4 Non-Intrusive Detection of Partial Discharge Activity ................5 What is Partial Discharge? ....................
  • Page 3 EA Technology UltraTEV Plus Operating Manual 2388L015 Using the virtual keyboard ....................39 Background Measurements ..................... 40 Recording Data ........................ 41 6.7.1 TEV recorded data ....................41 6.7.2 Cable PD recorded data ..................41 6.7.3 Ultrasonic recorded data ..................41 Viewing Survey Progress ....................
  • Page 4 EA Technology UltraTEV Plus Operating Manual 2388L015...
  • Page 5: Fcc Warning Statement

    EA Technology UltraTEV Plus Operating Manual 2388L015 FCC Warning Statement  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
  • Page 6: What Does The Ultratev Plus² Do

    EA Technology UltraTEV Plus Operating Manual 2388L015 What does the UltraTEV Plus² do? The UltraTEV Plus² is a versatile hand-held tool used to easily detect and classify Partial Discharge (PD) in a wide range of electrical equipment. The UltraTEV Plus² uses inbuilt TEV and Ultrasonic sensors and external accessories to detect the presence of potentially damaging PD in switchgear, cables and overhead line equipment.
  • Page 7: What's In The Box

    EA Technology UltraTEV Plus Operating Manual 2388L015 What’s in the Box? Part Kit 1 Kit 2 Kit 3 Kit 2 Kit 3 Upgrade Upgrade UltraTEV Plus Mains Charger Car Charger USB Lead 8GB MicroSD & SD adapter Neckband Headphones Ultrasonic...
  • Page 8: Important Information

    EA Technology UltraTEV Plus Operating Manual 2388L015 Important Information  The UltraTEV Plus is designed for use at ground potential only.  When testing electrical plant ensure that the metalwork is earthed before taking any measurements.  Maintain safety clearances between structures at high voltage and the instrument, its probes and the operator at all times.
  • Page 9: Non-Intrusive Detection Of Partial Discharge Activity

    EA Technology UltraTEV Plus Operating Manual 2388L015 Non-Intrusive Detection of Partial Discharge Activity What is Partial Discharge? Partial discharges are electrical discharges that do not completely bridge the insulation between electrodes. The magnitude of these discharges is usually small, however they cause progressive deterioration of insulation that may eventually lead to failure.
  • Page 10: Electromagnetic Discharge Activity

    EA Technology UltraTEV Plus Operating Manual 2388L015 The most sensitive method of detection is using an airborne ultrasonic Microphone centred at 40 kHz. This method is very successful at detecting partial discharge activity provided there is an air passage between the source and the Microphone.
  • Page 11: Using The Ultratev Plus²

    EA Technology UltraTEV Plus Operating Manual 2388L015 Using the UltraTEV Plus² TEV sensor Ultrasonic Sensor Photo Sensor Smart Ultrasonic Accessory Accessory Port Port Left Button Right Button Middle Button Home Button Audio out/headphone socket microSD card slot Micro USB charging port...
  • Page 12: Charging The Ultratev Plus

    Press and hold the Home Button for 1 second to turn on the UltraTEV Plus The UltraTEV Plus will boot displaying the EA Technology logo before proceeding to the main menu after a few seconds. To turn off the UltraTEV Plus...
  • Page 13: Notification Bar

    EA Technology UltraTEV Plus Operating Manual 2388L015 Notification Bar The notification bar is used to display basic status information about the UltraTEV Plus . It displays information such as Temperature, Humidity, Battery Level and other system information as shown below. Additional information such as icons depicting the type of accessory plugged in are also displayed here.
  • Page 14: Temperature & Humidity

    EA Technology UltraTEV Plus Operating Manual 2388L015 5.3.1 Temperature & Humidity The temperature and relative humidity reading is displayed on the notification bar only after connection of the sensor. The temperature and relative humidity sensor pictured below is connected to the Smart Accessory Port on the left hand side of the instrument.
  • Page 15: Main Menu

    EA Technology UltraTEV Plus Operating Manual 2388L015 Main Menu After powering up, the UltraTEV Plus will load up to the Main Menu as shown below. The Home Button can be used to navigate back to the Main Menu at any time.
  • Page 16: Tev/Cable Pd Menu

    EA Technology UltraTEV Plus Operating Manual 2388L015 TEV/Cable PD Menu The TEV/Cable PD screen, selected via the top left icon on the Main Menu contains different modes which can be used for the PD measurement. The Interpretation option is only applicable when in TEV mode...
  • Page 17: Measure Screen

    EA Technology UltraTEV Plus Operating Manual 2388L015 5.6.1 Measure Screen The Measure mode is common to both TEV and Cable PD. This mode displays TEV readings in dBmV (dB) or (if the RFCT accessory is connected) Cable PD readings in picoCoulombs (pC).
  • Page 18: Phase Plot

    EA Technology UltraTEV Plus Operating Manual 2388L015 5.6.2 Phase Plot The Phase Plot mode is common to both TEV and Cable PD. The upper section of the screen shows measurement values as detailed previously under the ‘Measure Screen’. The lower section contains a phase resolved intensity plot ‘Phase Plot’...
  • Page 19: Waveform

    EA Technology UltraTEV Plus Operating Manual 2388L015 5.6.3 Waveform The ‘Waveform’ mode is common to both TEV and Cable PD. When in Cable PD mode, values will be displayed in mA, whilst in TEV mode they will be measured in dBmV as below.
  • Page 20: Histogram

    EA Technology UltraTEV Plus Operating Manual 2388L015 5.6.4 Histogram This option (shown below) displays the number of events registered (y-axis) for a given amplitude (x-axis). This measurement option is useful for determining if more than one discharge source is present; two distinct groups of bars on this chart could mean there are two sources of discharge at the respective dB (or pC) levels.
  • Page 21: Interpretation

    This display is an easy to use software implementation of the TEV measurement interpretation guide produced by EA Technology using decades of experience. The original summary document giving an overview of the original guidelines for the interpretation of TEV measurements is included on the next page.
  • Page 22 EA Technology UltraTEV Plus Operating Manual 2388L015 Page 18 of 66...
  • Page 23: Noise Detection

    EA Technology UltraTEV Plus Operating Manual 2388L015 5.6.6 Noise Detection The UltraTEV Plus² incorporates a noise detection feature for TEV events. This feature continuously monitors the background noise level during a TEV reading and alerts the user if the level is approaching a point whereby the integrity of the reading may be adversely effected.
  • Page 24: Ultrasonic Screen

    EA Technology UltraTEV Plus Operating Manual 2388L015 Ultrasonic Screen The Ultrasonic screen shows measurements taken using either the inbuilt Ultrasonic sensor or the external Ultrasonic sensors (Contact Probe, Flexible Sensor or UltraDish) if connected. Ultrasonic magnitude is measured in dBµV and is displayed on the chart as phase angle (x- axis) against amplitude (y-axis).
  • Page 25: Ultrasonic Classification

    2388L015 5.7.1 Ultrasonic classification The Ultrasonic display on the UltraTEV Plus² includes the output of EA Technology’s proprietary ultrasonic classification algorithm. The algorithm processes measured ultrasonic data in real time to give an indication whether the input data is a background noise source or partial discharge activity.
  • Page 26: Context Menu

    EA Technology UltraTEV Plus Operating Manual 2388L015 Context Menu Pressing the Left Button whilst in TEV, Cable PD or Ultrasonic modes brings up the Context Menu as shown below. The Context Menu consists of a number of items with only those relevant to the current mode of operation visible at any time.
  • Page 27: Filters

    EA Technology UltraTEV Plus Operating Manual 2388L015 5.8.2 Filters Select the filter icon to change the filter properties; this option is only enabled when in Cable PD Measurement Mode and enables noise to be filtered from the cable PD measurement.
  • Page 28 EA Technology UltraTEV Plus Operating Manual 2388L015 The current status of the phase reference is indicated by the colour of the phase readout. A red phase display indicates that a phase lock has not been achieved. A continous red phase display would neccesitate the change of mode.
  • Page 29: Settings Screen

    EA Technology UltraTEV Plus Operating Manual 2388L015 Settings Screen To access the settings page, click the Settings icon on the Main Menu and the screen shown below will be displayed. 5.9.1 System Settings  Key Beep – allows the turning ON/OFF of the audible beeps when any of the buttons are pressed.
  • Page 30 EA Technology UltraTEV Plus Operating Manual 2388L015  Language – select this option to change the UltraTEV Plus² display language.  Time/Date – select this option to change the Time and Date settings on the UltraTEV Plus². The time zone can also be changed here as shown below.
  • Page 31: Measurement Settings

    EA Technology UltraTEV Plus Operating Manual 2388L015 5.9.2 Measurement Settings The Alarm Mode can be toggled on and off in this option. When the Alarm mode is activated, the inbuilt beeper of the UltraTEV Plus² will be activated whenever the set Red threshold level has been exceeded.
  • Page 32: Network Settings

    EA Technology UltraTEV Plus Operating Manual 2388L015 5.9.3 Network Settings This section allows the setting of the Wi-Fi feature of the UltraTEV Plus². The Wi-Fi functionality can be switched on/off using the toggle button shown above. Select ‘Network Connect’ above to connect it to a Wi-Fi network.
  • Page 33: About

    EA Technology UltraTEV Plus Operating Manual 2388L015 Using the on-screen keyboard, enter the Wi-Fi password and then the Middle Button save the network. The connection status of the UltraTEV Plus² can be viewed by selecting ‘Network Status’. 5.9.4 About The about screen displays a summary of the UltraTEV Plus² components including both hardware and software version numbers.
  • Page 34 EA Technology UltraTEV Plus Operating Manual 2388L015 To install a firmware update from the MicroSD card, press the “Check MicroSD for Update” button on the above screen. The MicroSD card will be checked for any available updates, and details populated on the display as shown below. To install the update found, press the tick icon on the right of the menu bar and await the process to complete.
  • Page 35: Reset All Settings

    EA Technology UltraTEV Plus Operating Manual 2388L015 5.9.6 Reset All Settings This option can be used to reset the UltraTEV Plus² back to the default settings. Upon pressing the option a notification will appear asking for the action to be confirmed.
  • Page 36: File Browser

    EA Technology UltraTEV Plus Operating Manual 2388L015 5.10 File Browser The File Browser screen can be used to manage files and folders stored on the UltraTEV Plus²’s microSD card. To access the file browser, click File icon on the Home screen.
  • Page 37: Screenshot

    EA Technology UltraTEV Plus Operating Manual 2388L015 5.11 Screenshot The UltraTEV Plus² allows the user to capture an image of the screen at any time. To initiate a capture press both the left and right hand buttons simultaneously for two seconds.
  • Page 38: Function Check

    EA Technology UltraTEV Plus Operating Manual 2388L015 5.12 Function Check The UltraTEV Plus²’s function checker is designed to allow users to verify the functionality of their instrument using in built test sources. The Function Check display option can be used to toggle these inbuilt test sources.
  • Page 39: Survey

    EA Technology UltraTEV Plus Operating Manual 2388L015 Survey The Survey mode of the UltraTEV Plus² is a powerful yet easy way to collect and store data from a range of assets. Data from TEV, Cable PD or Ultrasonic measurement modes can be recorded and stored with corresponding metadata linking the data and its associated context.
  • Page 40: Ad-Hoc Measurement

    EA Technology UltraTEV Plus Operating Manual 2388L015 switchgear and conditions. The form field can be populated using the inbuilt virtual keyboard or a drop down list of available options. The Notification bar changes from blue to green to indicate a survey is...
  • Page 41 EA Technology UltraTEV Plus Operating Manual 2388L015 Form Name Substation Field Description Behaviour Name Name of the substation being surveyed Pressing the input field will show the virtual keyboard Type Type of the substation being surveyed Pressing the input field will show a...
  • Page 42: Using Populated Lists

    EA Technology UltraTEV Plus Operating Manual 2388L015 Form Name Conditions Field Description Behaviour Background Background metalwork TEV value Pressing the input field will cause a Metal background TEV measurement to be performed Background Background Air TEV value Pressing the input field will cause a...
  • Page 43: Using The Virtual Keyboard

    EA Technology UltraTEV Plus Operating Manual 2388L015 option is selected a virtual keyboard prompt will be displayed for custom input. If the cross in the menu bar is pressed, the list will be closed and no input recorded Using the virtual keyboard The virtual keyboard allows custom text to be input.
  • Page 44: Background Measurements

    EA Technology UltraTEV Plus Operating Manual 2388L015 Background Measurements The background measurements fields on the survey metadata forms have special behaviour, pressing the input field triggers the UltraTEV Plus² to start measuring the TEV level for a ten second period. Following this, the average measurement for the period is stored.
  • Page 45: Recording Data

    EA Technology UltraTEV Plus Operating Manual 2388L015 Recording Data Once a survey has been started data can be recorded from any TEV, Cable PD or Ultrasonic displays. The same data is recorded for TEV or Cable PD independent of which TEV/Cable PD screen is currently displayed.
  • Page 46: Viewing Survey Progress

    EA Technology UltraTEV Plus Operating Manual 2388L015 Viewing Survey Progress The progress of a survey can be viewed at by navigating to the Survey menu then pressing ‘View Progress’. The view progress display shows a top view of a switchgear panel with the different components making up a panel separated out.
  • Page 47: Reviewing Results

    EA Technology UltraTEV Plus Operating Manual 2388L015 Reviewing Results Data collected during Survey mode or though ad-hoc recording is stored on the UltraTEV Plus²’s MicroSD card. To facilitate viewing of the data the UltraTEV Plus² provides three methods of connection: ...
  • Page 48: Data Analysis Screens

    EA Technology UltraTEV Plus Operating Manual 2388L015 ‘index.html’. Extracting the zip file and then opening the ‘index.html’ file inside this folder will direct you to the analysis pages. Data Analysis Screens The UltraTEV Plus has a web interface for analysing data captured by the instrument. These analysis pages can be accessed through a web browser or downloaded for offline analysis as detailed above.
  • Page 49: Tev & Cable Pd Analysis Screen

    EA Technology UltraTEV Plus Operating Manual 2388L015 7.3.1 TEV & Cable PD Analysis Screen Both TEV and Cable PD recorded data share the same suite of analysis screens. Once a TEV or Cable PD measurement has been selected from the index page a new tab will open in the browser displaying the analysis page corresponding to the measurement selected.
  • Page 50: Ultrasonic Analysis

    EA Technology UltraTEV Plus Operating Manual 2388L015 using the up/down arrows next to the waveform number. The ‘Show All’ button can be used to show all waveforms on the same graph. 7.3.2 Ultrasonic Analysis Once an ‘Ultrasonic’ measurement has been selected on the index page, a new tab will open in the browser with the analysis page corresponding to the measurement selected.
  • Page 51: Detecting Partial Discharge Using The Ultratev Plus²

    EA Technology UltraTEV Plus Operating Manual 2388L015 Detecting Partial Discharge using the UltraTEV Plus² Due to the tri-sensor capability, the UltraTEV Plus² is able to detect Partial Discharge activity on the surface of insulation using Ultrasonic detection, internal to insulation by measuring TEV signals and in cables and cable accessories using the RFCT accessory.
  • Page 52: Measuring Tev

    EA Technology UltraTEV Plus Operating Manual 2388L015 8.1.2 Measuring TEV Switch on the UltraTEV Plus² and wait until home menu is displayed. Press the TEV icon on the home menu then choose which TEV display is required. The ‘Interpretation’ display is recommend for first pass with the advanced functionality of the other modes being utilised to further inform the user once a signal is detected.
  • Page 53: Cable Pd Measurement

    UltraTEV Plus². The RFCT connects to the Smart accessory port found on the left hand side of the instrument. EA Technology RFCTs are designed to be installed by suitably competent operators on cable earth/ground straps which are suitably and efficiently connected to earth/ground to maintain safety.
  • Page 54: Ultrasonic Measurement

    EA Technology UltraTEV Plus Operating Manual 2388L015 RFCTs, connecting leads and test equipment do not provide protection against high voltage. Ensure that the accessory is only connected to cables at earth potential. Press the Cable PD icon on the home menu and proceed to press on the Measure option.
  • Page 55 EA Technology UltraTEV Plus Operating Manual 2388L015 Due to the gain of the UltraDish, readings taken with the UltraDish cannot be compared to readings taken with the Internal Sensor, the Flexible Sensor or the Contact Probe. This accessory is available with the Kit 3 package. To discuss procuring this accessory please contact the product support team via email: product-support@eatechnology.com...
  • Page 56: Measuring Ultrasonic Using The Flexi Probe Sensor Accessory

    EA Technology UltraTEV Plus Operating Manual 2388L015 8.3.3 Measuring Ultrasonic using the Flexi Probe sensor Accessory The Flexible Sensor provides a means of reaching inaccessible parts on the switchgear. The sensor is mounted at the end of a flexible goose-neck which allows the angle of the sensor to the handle to be adjusted.
  • Page 57: Ultrasonic Measurement Using The Contact Probe Accessory

    EA Technology UltraTEV Plus Operating Manual 2388L015 8.3.4 Ultrasonic Measurement using the Contact Probe Accessory The Ultrasonic Contact Probe is provided to enable discharges to be detected in enclosed areas where there is no direct air path from the discharge source to the sensor. The Probe connects to the external sensor connector and is clamped on to the area of interest using the magnets surrounding the sensor plate.
  • Page 58: Using The Ultrasonic Contact Probe

    EA Technology UltraTEV Plus Operating Manual 2388L015 8.3.5 Using the Ultrasonic Contact Probe The Ultrasonic Contact Probe should be used if there is not a direct path between the PD source and instrument sensor as shown in the second image below. However, it must not be used if the tank containing the expected PD source is separated with another layer (shown in the third image).
  • Page 59: Detection, Measurement And Localisation Of The Partial Discharge

    EA Technology UltraTEV Plus Operating Manual 2388L015 8.3.6 Detection, Measurement and Localisation of the Partial Discharge Detection of the Partial Discharge using the Ultrasonic Contact Probe is based on the PD pattern recognition carried out by operators. The audio signature of a Partial Discharge detected by the Contact Probe is similar to those obtained using airborne sensors.
  • Page 60 EA Technology UltraTEV Plus Operating Manual 2388L015  Solid state – suitable for long term monitoring but does not offer as good coupling as oil based.  Use of existing stickers on the switchgear such as ‘danger’ notices The last image shows the application of pressure to the Ultrasonic Contact Probe against the asset under investigation.
  • Page 61: Sources Of Noise And Phantom Signals

    EA Technology UltraTEV Plus Operating Manual 2388L015 8.3.8 Sources of Noise and Phantom Signals The following images present some examples of how unwanted signals may be introduced during the PD detection process when using the Ultrasonic Contact Probe. These can be categorised as sources of noise and sources of phantom PD signals.
  • Page 62: Ultratev Plus² Specification

    EA Technology UltraTEV Plus Operating Manual 2388L015 Specification UltraTEV Plus² TEV Measurements Sensor: Capacitive Measurement Range: 0 – 60 dBmV Measurement Bandwidth: 3 – 80 MHz Resolution: Accuracy: ±1dB Max Number of Pulses/Cycle: 1953 at 50Hz or 1627 at 60Hz...
  • Page 63: Hardware

    EA Technology UltraTEV Plus Operating Manual 2388L015 Hardware Enclosure: Self-coloured vacuum formed plastic case Screen: 3.5” TFT Touchscreen LED Backlight 640 x 480 Resolution Indicators: Charging indicator LED Controls: 4 x Push-Buttons Connectors: Micro USB connection port MicroSD Slot 2 x Accessory connection ports Headphones: 3.5mm jack;...
  • Page 64: Battery Charger

    EA Technology UltraTEV Plus Operating Manual 2388L015 Battery Charger Rated Voltage: 100 – 240 AC Frequency: 50 - 60Hz Charger Output Current: Battery Charging Current: 1.8A @ 5V nominal Dimensions: 61.89mm x 39mm x 32.3mm Weight: 65g (approx.) Operating Temperature: 0 - 40°C...
  • Page 65: Declaration Of Conformity

    EA Technology UltraTEV Plus Operating Manual 2388L015 10. Declaration of Conformity Manufacturers Name: EA Technology Ltd Manufacturers Address: Capenhurst Technology Park Capenhurst Chester CH1 6ES Type of Equipment: UltraTEV Plus² Model Number: UTP2 I hereby declare that the equipment specified above is tested to and conforms with the...
  • Page 66: Maintenance

    EA Technology products and accessories are warranted against defects in material and workmanship for twelve months from the date of despatch from our premises. During the warranty period, EA Technology will, at its option, either repair or replace products, parts or accessories which prove defective.
  • Page 67: Calibration

    15. Waste Electrical and Electronic Equipment Directive (WEEE) EA Technology is a member of an approved compliance scheme as defined by the WEEE directive. When an EA Technology product reaches the end of its operational life, it must be recycled by a licensed waste management operator, or returned to EA Technology for recycling.
  • Page 68: Contact Us

    EA Technology UltraTEV Plus Operating Manual 2388L015 17. Contact Us Head Office EA Technology Ltd Capenhurst Technology Park Chester, UK, CH1 6ES Tel: +44 (0)151 339 4181 For details of our international offices and distributors, please visit our website: www.eatechnology.com/contact-us...
  • Page 69: Record Of Changes

    EA Technology UltraTEV Plus Operating Manual 2388L015 18. Record of Changes Date Version Author(s) Notes 2388L011 April 2016 Gareth Devine First Issue 2388L012 April 2016 Gareth Devine Second Issue May 2016 2388L013 Gareth Devine Third Issue August 2016 2388L014 Gareth Devine,...
  • Page 70 © EA Technology Ltd 2016 EA Technology Limited, Capenhurst Technology Park, Capenhurst, Chester, CH1 6ES, UK Tel: +44 (0)151 339 4181 Fax: +44 (0)151 347 2404 http://www.eatechnology.com...
  • Page 71 Main reception: +44(0) 151 339 4181 EA Technology, Capenhurst Technology Park, Australia | China | Singapore | UAE | Europe | USA Capenhurst, Chester, CH1 6ES, United Kingdom...
  • Page 72  Achieve the latest standards  Develop their power skills  www.eatechnology.com Main reception: +44(0) 151 339 4181 EA Technology, Capenhurst Technology Park, Australia | China | Singapore | UAE | Europe | USA Capenhurst, Chester, CH1 6ES, United Kingdom...

Table of Contents