Component Diagram; Connections And Setup; Cold Start; Cold Start Procedures - Sony SSC-SD26P Operating Instructions Manual

Color video camera dynaview
Table of Contents

Advertisement

Component Diagram

1 Composite video cable (BNC cable)
2 Alarm input line
3 Alarm output line
4 AC 24V power cable (with ground line)
5 RS-485 signal line (not supplied with adapter)
6 fastener (not supplied)
7 Cable
8 Sun shield (optional)
9 Connector ring
0 Water-proof cover
qa Main unit
qs lens
qd Water-proof transparent housing
qf Safety cable
6
Component Diagram / Connections and setup / Cold Start
1
2
3
4
5
6
7
8
9
0
qa
qs
qd
qf

Connections and setup

Monitor
RS485
Grounding line (black)
Alarm input line 1 (brown)
Alarm input line 2 (red)
Alarm input line 3 (orange)
Alarm input line 4 (yellow)
Alarm input line 5 (green)
Alarm input line 6 (blue)
Grounding line (purple)
Grounding line (grey)
Alarm output normal ON (white)
Alarm output Com (sky-blue)
Alarm output normal OFF (pink)

Cold Start

When the camera is started in low temperature, it may
operate improperly due to low inner temperature.
Therefore, cold start operation should be performed if it
is necessary to start the camera in the envionment of –40
to –5 due to blackouts or other reasons.

Cold Start procedures

1
Turn on the power, and turn off the camera after the
heater operates for 1 hour, and then turn off.
2
Turn on the camera again.
GND
Alarm In 1
Alarm In 2
Alarm In 3
Alarm In 4
Alarm In 5
Alarm In 6
GND
Alarm
GND
inputs
Alarm
Alarm Out Open
outputs
Alarm Out Com
Alarm Out Close
AC 24V power adapter
Adapter (not supplied)
Keypad controller (not
supplied)