Tektronix WFM720UP Instructions Manual
Tektronix WFM720UP Instructions Manual

Tektronix WFM720UP Instructions Manual

Waveform

Advertisement

Quick Links

WFM720UP, WFM820UP, and WFM830UP Upgrades
xx
for the WFM7200, WFM8200, and WFM8300
Waveform Monitors
ZZZ
Instructions
Warning
The servicing instructions are for use by qualified personnel
only. To avoid personal injury, do not perform any servicing
unless you are qualified to do so. Refer to all safety summaries
prior to performing service.
www.tektronix.com
*P075100103*
075-1001-03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WFM720UP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tektronix WFM720UP

  • Page 1 WFM720UP, WFM820UP, and WFM830UP Upgrades for the WFM7200, WFM8200, and WFM8300 Waveform Monitors Instructions Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so. Refer to all safety summaries prior to performing service.
  • Page 2 Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material.
  • Page 3: Table Of Contents

    Upgrade Installation ....................Verify the Currently Installed Options............... How to Prevent Electrostatic Discharge..............Install the Software Upgrade ................Install the Option Hardware ................. Install the Option Software Key................Verify the Upgrade ....................Quick Verification .................... Detailed Verification..................WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 4 Table of Contents WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 5: General Safety Summary

    Do Not Operate With Suspected Failures. If you suspect that there is damage to this product, have it inspected by qualified service personnel. Avoid Exposed Circuitry. Do not touch exposed connections and components when power is present. WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 6 DANGER indicates an injury hazard immediately accessible as you read the marking. WARNING indicates an injury hazard not immediately accessible as you read the marking. CAUTION indicates a hazard to property including the product. The following symbol(s) may appear on the product: WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 7: Kit Description

    Kit Description Kit Description This document provides instructions for installing the video and audio upgrades listed below into an existing Tektronix WFM7200, WFM8200, or WFM8300 waveform monitor. Table 1: Supported upgrades Video Upgrades WFM820UP WFM830UP WFM720UP Description Option 2SDI Adds a second SDI input module, adding 2 additional SDI inputs that support 3G-SDI, HD-SDI, and SD-SDI.
  • Page 8 Option PROD Adds Advanced Gamut Monitoring Package (Spearhead Display and Luma Qualified Vector Display). Option DAT Adds data analysis capabilities. Allows for logic-level view of video and embedded audio data stream and ANC data extraction. WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 9: Products

    Kit Description Products The following Tektronix products are supported by this kit: WFM7200 All instruments WFM8200 All instruments WFM8300 All instruments Required Tools The following table lists the tools required to install the upgrade. Table 2: Required tools Name Description...
  • Page 10: Kit Parts Lists

    WASHER, LOCK; 0.521 ID, INT, 0.025 THK, STEEL, ZINC FINISH NOTE. Once the hardware is installed, you must download the software to activate Option 2SDI. Go to www.tektronix.com/downloads. (See page 11, Install the Software Upgrade.) WFM820UP CPS Table 4: Option CPS parts list...
  • Page 11 1 EA 075-1001-XX INSTRUCTIONS; WFM720UP, WFM820UP, AND WFM830UP UPGRADES 1 EA 672-6478-XX CIRCUIT BD SUBASSY; DIGITAL AND ANALOG AUDIO 1 EA 131-7430-XX CONN,DSUB; SLDR CUP,MALE,STR,62 POS,0.100 CTR,30 GOLD 1 EA 200-4804-XX COVER; SHIELD,ELEC CONN,37 POS DSUB,ZINC WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 12 CIRCUIT BD SUB ASSY 1 EA 131-7430-XX CONN,DSUB; SLDR CUP,MALE,STR,62 POS,0.100 CTR,30 GOLD 1 EA 200-4804-XX COVER; SHIELD,ELEC CONN,37 POS DSUB,ZINC 1 EA 119-7167-XX CIRCUIT BD ASSY; CAT552 DOLBY E/DIGITAL DECODER MODULE; 72 PIN SIMM; SAFETY CONTROLLED WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 13: Upgrade Installation

    1. Power on the instrument you are upgrading. 2. Press the CONFIG button on the front panel. 3. Navigate to Utilities > View Instrument Options. 4. Make a list of the installed options. List installed options WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 14: How To Prevent Electrostatic Discharge

    5. Do not allow anything capable of generating or holding a static charge on the work surface. 6. Handle circuit boards by the edges or hold onto grounded shields when possible. 7. Do not slide circuit boards over any surface. WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 15: Install The Software Upgrade

    Instrument Software version number 3. Verify the latest version of software at the Tektronix Web site: a. Use the Web browser on a PC to navigate to the following Tektronix Web site: http://www.tektronix.com/downloads b. On the Downloads Finder Web page, search by model number (such as WFM8300) and filter by software and software type to locate the...
  • Page 16 Once the instrument has started to erase internal flash, DO NOT remove power from the instrument. If you do so, the instrument flash will be corrupted. The instrument will have to be sent to a Tektronix factory service center to have the system software restored.
  • Page 17 IP address if you are using an Ethernet cable to connect the PC directly to the instrument. NOTE. If you selected DHCP mode, the network automatically assigns the instrument an IP address. e. Press the CONFIG button on the front panel to close the menus. WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 18 Figure 1: Sample of transfer.exe window after the upgrade is complete 6. If the instrument did not reboot at the completion of the software upgrade, remove and then reapply power to the instrument to cause it to reboot. WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 19: Install The Option Hardware

    (See page 28, Install the Option Software Key.) The hardware installation procedure consists of the following steps: Removing the instrument cover and the module guide brackets Installing the new hardware Reinstalling the module guide brackets and the instrument cover WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 20 (See page 10, How to Prevent Electrostatic Discharge.) 4. Remove the screws from the chassis cover. (See Figure 3.) Save the screws for reinstallation. WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 21 6. Remove the module guide brackets. (See Figure 4.) Note that the brackets are keyed to the fit on the chassis in only one direction. Figure 4: Removing the module guide brackets (option boards shown) WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 22 Figure 5: Removing the Option EYE/PHY/PHY3 and CPS rear panel screws WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 23 J16 and J24 on the Main Interface board. The recessed flange on the left side of the module rear panel slides behind the adjacent rear panel. (See Figure 6.) Figure 6: Installing the Option EYE or PHY or PHY3 board WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 24 Option CPS and Option 2SDI boards occupy the same location in the instrument. If your instrument already contains an Option CPS board, it must be removed. You can reinstall the removed option module if you require its functionality. WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 25 Install the option software key. (See page 28, Install the Option Software Key.) NOTE. Once the hardware is installed, you must download the software to activate Option 2SDI. Go to www.tektronix.com/downloads. (See page 11, Install the Software Upgrade.) WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 26 Reinstall the instrument module support brackets and cover by performing the removal procedure in reverse order. (See page 16, Remove the Instrument Cover and Module Guide Brackets.) c. Install the option software key. (See page 28, Install the Option Software Key.) WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 27 4. Install the new audio module into the instrument, fully inserting the module connector into J4 on the Main Interface board. The recessed flange on the left side of the module rear panel slides behind the adjacent rear panel. WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 28 An example of a suitable cable is Belden 8451, which is a shielded twisted pair cable. Alternatively, you can purchase an audio breakout cable (Tektronix part number 012-1688-00), which provides a two meter cable with XLR connectors for all twelve inputs and eight outputs.
  • Page 29 Figure 11: Removing the audio rear panel screws WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 30 Fully insert the connector on the Dolby E module into the socket on the audio module, and then rotate the Dolby E module in towards the audio module until the Dolby E module latches into position. (See Figure 13.) Figure 13: Installing the Dolby E module WFM720UP, WFM820UP, and WFM830UP Upgrades...
  • Page 31 An example of a suitable cable is Belden 8451, which is a shielded twisted pair cable. Alternatively, you can purchase an audio breakout cable (Tektronix part number 012-1688-00), which provides a two meter cable with XLR connectors for all twelve inputs and eight outputs.
  • Page 32: Install The Option Software Key

    On the PC, open your Web browser application. b. In the address bar of the Web browser, enter the IP address of the instrument you are upgrading. This opens the Tektronix WFM8200/WFM8300 Remote Interface screen. c. Click the Instrument Options link to open the Active WFM8200/8300 Options screen.
  • Page 33: Verify The Upgrade

    NOTE. If the option(s) you just installed are not listed or if your previously installed options are not listed, contact Tektronix for assistance. 3. Verify that the instrument passes the advanced diagnostic tests by performing the following steps: a.

This manual is also suitable for:

Wfm820upWfm8200Wfm830upWfm7200Wfm8300

Table of Contents