String-F Time Code O/P On P4; String-G Time Code O/P On P4 - Tektron TCG 01-G User Manual

Time code
Table of Contents

Advertisement

Example
<SOH>2004:112:12:34:36?<CR><LF>

String-F Time Code O/P on P4

About
This string complies with the protocol required to drive Vorne type Time
Displays.
Timing
The string is transmitted once every second, with the leading edge of the
Comms
9600bps, 8-bit ASCII, no parity
Definition
<CR><LF>1100<CR><LF>44hhmmss<CR><LF>54ddd<CR><LF>
<CR><LF>45HHMMss<CR><LF>55DDD<CR><LF><BEL>
Placeholder
Content
1100
44
hh
mm
ss
54
ddd
Local day of year:
45
HH
MM
55
DDD
<BEL>
HEX 07
<CR><LF>
Carriage Return Line Feed Pair: HEX 0D 0A

String-G Time Code O/P on P4

About
This general time string is used predominantly in Europe.
Timing
The string is transmitted once every second, with the leading edge of the
Comms
9600bps, 8-bit ASCII, no parity
Definition
<STX>swhhmmssddMMyy<LF><CR> <ETX>
TEK-TCG 01-G-Manual-v5-092016
© 2016 by Tekron International Limited. All Rights Reserved. All trademarks are the property of their respective holders. The
information in this document is provided for informational use only and is subject to change. For further information or support, go to
www.tekron.com.
Interpretation
2004, day 112, 12:34:36pm, >100us sync error
(means local time follows)
P a g e
| 32
.
.
www.tekron.com

Advertisement