4. BACK PANEL INPUTS AND OUTPUTS

ANT: Antenna Connector (SMA Connector)

ANT is the GNSS antenna input port. The antenna port provides an interface for an
external active antenna via low-loss coaxial cable: 50 Ω impedance. 5 V DC @ 50 mA max
is supplied to power an active antenna. The total combined gain of the antenna system
(antenna plus cable and connectors) should fall in the range of 10 to 35 dB, the optimum
being 22 dB.
If the Fiber-Slave option is ordered, the antenna is replaced by a fiber input port.
Care should be taken to ensure that the connector is not cross-threaded when
attaching the antenna lead-in cable. The connector should be tightened firmly by
hand only. Do NOT over-tighten!

Antenna Cable Considerations:

Note: The following figures are based on an average GNSS signal strength of -130dBm at sea level.
CNT-240
CNT-400
A lightning protection device should be inserted into the antenna lead. A suitable device complete
with additional cable connectors, a connector crimping tool and mounting hardware is available as an
option (FACTORY HARDWARE OPTIONS). Introduction of the lightning protector does not degrade
the performance of the antenna system.

P2, P3: Programmable Outputs (2-pin [3.81 mm] / BNC or ST Fiber)

Electrical and Physical Configuration

Each output port may be fitted at the factory according to the following:
Electrical
Electrical Specification
TEK-TCG 01-G-Manual-v5-092016
© 2016 by Tekron International Limited. All Rights Reserved. All trademarks are the property of their respective holders. The
information in this document is provided for informational use only and is subject to change. For further information or support, go to
www.tekron.com.
32.8 dB/100 m (10dB/100ft). Plus 1 dB/connector
Approx. Optimum Length Range: 18 to 42 meters
Approx. Maximum Length Range: 12 to 70 meters
16.73 dB/100 m. Plus 1 dB/connector
Approx. Optimum Length Range: 34 to 79 meters
Approx. Maximum Length Range: 23 to 129 meters
P a g e
| 11
Physical
www.tekron.com