P8: Ecp Ethernet Communication Port (Rj45 Connector) - Tektron TCG 01-G User Manual

Time code
Table of Contents

Advertisement

priority over P6B). If the unit is optioned for PTP operation, it can also sync to time from a distant
PTP Master clock.
If all sync is lost, the TCG 01-
the alarm condition is signaled. When sync is restored, the alarm condition is retained for 5 seconds
before being cancelled.
The alarm outputs are Type A (normally-open) dry contact types (implemented using solid state
relays).
Normally-Open
convention used in the TCG 01-G is to have the alarm relays energized during normal operation, and
de-energized in the alarm state. In the case of all power to the clock being lost, all of the alarm relays
negative terminals respectively. The wiring size is up to 1.00 mm²; contact rating: 200 V, 150 mA DC
or 150 V, 100 mA AC.

P8: ECP Ethernet Communication Port (RJ45 Connector)

port whilst the ACT LED will be on when there is activity on either the transmit or receive pair.
This port is also used to configure the clock via the Tekron Configuration Tool which is available for
download on the TCG 01-G page on the Tekron website at http://www.tekron.com/tcg-01-g.
TEK-TCG 01-G-Manual-v5-092016
© 2016 by Tekron International Limited. All Rights Reserved. All trademarks are the property of their respective holders. The
information in this document is provided for informational use only and is subject to change. For further information or support, go to
www.tekron.com.
(configurable in the Configuration Tool).
The Ethernet port (ETH1), features a RJ45 connector and supports
10/100 Mbps, Auto MDX & Auto Negotiate. The LEDs convey Link (LNK)
and Activity (ACT) status for the port.
The LNK LED will be on when the unit is connected to a valid Ethernet
-energized state of the relay. The
act). The + and - symbols represent the positive and