P4: Serial Port and Programmable Output (DB9 Connector)

Do NOT over-tighten the securing screws of the connector!
The following signals are present on P4 (DCE configuration only):
 Pin 1: RS232 level (-9V to +9V) programmable output.
 Pin 2: RS232 level serial string.
 Pin 5: RS232 signal ground.
 Pin 4 & Pin 6: RS422 level 5V) differential programmable output.
 Pin 8 & Pin 9: RS422 level serial string.
The RS232/RS422 signal lines are not isolated from each other, but the port as a whole has an
isolation rating of 2.5 kV from all other ports.

P4 Serial Strings

The serial port can be configured to output any one of a number of different serial time messages on
a broadcast basis. The serial port runs at a user configurable data rate between 1200 and 38400 bps
(available rates are 1200, 2400, 4800, 9600, 19200 and 38400 bps). Message formats typically
operate at 9600 baud, 8-bit with no parity, no flow control and 1 stop bit. Most messages are
transmitted once per second.
A wide range of message strings and protocols can be output on this port. They include:
 NTS protocol (transmits once per minute)
 IRIG J-17
 Seven pre-set messages, String/Tekron A G for compatibility with most IED.
 NMEA ZDA and RMC messages
 GNSS Binary/Messages, these are subject to change without notice.
See Appendix (SERIAL OUTPUT STRINGS) for details on each of the message string formats.
A common application for the programmable output on P4-pin 1 (RS232 level) is to provide an
independent drive to an RS232-Fiber converter unit for use in transporting time-code/pulse signals
to a distant location. (Tekron manufactures a range of interface devices (ITRs) that include such
converters.
connect to an external PC, and used in conjunction with pin 5 (signal return).

P4-pin 1 Programmable Output

The user may configure the P4-pin 1 output to operate with inverted or non-inverted polarity, and:
 A user-configurable number of pulses per second, minute, hour, day with adjustable
pulse-width and offset.
 IRIG-B and DCF-77 time codes.
TEK-TCG 01-G-Manual-v5-092016
© 2016 by Tekron International Limited. All Rights Reserved. All trademarks are the property of their respective holders. The
information in this document is provided for informational use only and is subject to change. For further information or support, go to
www.tekron.com.
If not requested otherwise, the TCG 01-G is normally shipped as a DCE
can be used to connect directly to a standard PC serial port. A suitable 2 m
cable is included with each TCG 01-G purchase. The CTS and DSR lines are
permanently asserted. As the serial outputs are usually precisely timed
messages, there is no provision for either hardware or software flow control.
P a g e
-
Socket-to-Socket 9-way data cable
-way cable optionally used to
| 13
www.tekron.com

Advertisement

Table of Contents
loading

Table of Contents