Measure Dc Voltage; Set Measurement Range; Save Dc Voltage Readings - Fluke BT520 User Manual

Battery analyzer
Hide thumbs Also See for BT520:
Table of Contents

Advertisement

BT520
Users Manual

Measure DC Voltage

The Product can measure dc voltage. It also shows the polarity on the display.
To measure dc voltage, turn the rotary switch to . See Figure 3-3 for connections.

Set Measurement Range

In this measurement mode, auto range is used by default. When the input signal reaches
110 % of the upper limit of the current range, the Product automatically increases a
range. When the input signal reaches 90 % of the lower limit of the current range, the
Product automatically decreases a range.
To manually set the range, push  to cycle through 6 V, 60 V, and 600 V.

Save DC Voltage Readings

In Meter mode, push the Save softkey to save the current dc voltage reading and the
timestamp. All saved data is stored in chorological order.
In Sequence mode, push the Save softkey to save the current dc voltage reading and
the timestamp. The current battery number automatically increases by 1. The cell that
corresponds to the tested point becomes full, and the cursors move forward.
3-14
Save
UPS
Vdc
Figure 3-3. Measure DC Voltage
hsn019.eps

Hide quick links: