Sanyo VPC-WH1W Service Manual page 24

Dual camera
Table of Contents

Advertisement

Adjustment method:
1. Set the siemens star chart 100 ± 0.5 cm from lens surface
so that it becomes center of the screen (zoom wide and
tele). Set the camera and the chart in a straight, and do not
put optical systems (mirror and conversion lens etc.)
2. Double-click on the DscCalDi.exe.
3. Click the "Focus", and Click the "Yes".
4. Lens adjustment value will appear on the screen.
5. Click the OK.
DscCalDi
Focus Result
!
AF_TEMP_AD: 479
AF_WIDE: 9
AF_MID1: 11
AF_MID2: 15
AF_MID3: 25
AF_MID4: 26
AF_MID5: 24
AF_MID6: 19
AF_MID7: 22
AF_MID8: 22
AF_TELE: 17
Adjustment value determination is effectuated using below val-
ues.
The adjustment values fulfill the conditions below, they are de-
termined as within specifications.
Adjustment value determination
AF_TEMP_AD: ATAD
ATAD: adjustment value of focus temperature A/D
(264<ATAD<837)
AF_WIDE: ZW
ZW: adjustment value of focus at zoom position wide
(–77<=ZW<=78)
AF_MID1: ZM1
ZM1: adjustment value of focus at zoom position middle1
(–96<=ZM1<=96)
AF_MID2: ZM2
ZM2: adjustment value of focus at zoom position middle2
(–118<=ZM2<=117)
AF_MID3: ZM3
ZM3: adjustment value of focus at zoom position middle3
(–147<=ZM3<=97)
AF_MID4: ZM4
ZM4: adjustment value of focus at zoom position middle4
(–199<=ZM4<=148)
AF_MID5: ZM5
ZM5: adjustment value of focus at zoom position middle5
(–234<=ZM5<=213)
AF_MID6: ZM6
ZM6: adjustment value of focus at zoom position middle6
(–240<=ZM6<=241)
AF_MID7: ZM7
ZM7: adjustment value of focus at zoom position middle7
(–259<=ZM7<=230)
x
OK
AF_MID8: ZM8
ZM8: adjustment value of focus at zoom position middle8
(–286<=ZM8<=286)
AF_TELE: ZT
ZT: adjustment value of focus at zoom position tele
(–306<=ZT<=306)
4. AWB Adjustment
Camera
Preparation:
POWER switch: ON
Setting of pattern box:
Color temperature: 3100 ± 20 (K)
Luminance: 900 ± 20 (cd/m
Adjusting method:
1. Set a distance of 0.5-1.0 cm between the pattern box and
the camera. (Do not enter any light.)
2. Double-click on the DscCalDi.exe.
3. Click the AWB, and click the Yes.
4. AWB adjustment value will appear on the screen.
5. Click the OK.
Dsc Calibration
AWB Results:
1:
WB=216,503,658
CHECK=128,128,146
WB_FS=262,486,455
CHECK_FS=128,128,133
IRIS_PWM1=190,157
IRIS_PWM2=142,126
IRIS_PWM3=118,104
IRIS_PWM4=91
MS=2796,1291
MS_M=2301,2055
MS_C=1843,1781
MS_C2=1737,1705
MS_C3=1709,1674
When all of the AWB adjustment screen
is not displayed, use a scroll bar.
– 24 –
Pattern box
(color viewer)
2
)
x
MS_C4=1577,1506
OK
MS_C5=1415
MS_Z=3008,1291
Copy
MS_M_Z=2403,2081
MS_C_Z=1841,1781
MS_C2_Z=1737,1705
MS_C3_Z=1709,1674
MS_C4_Z=1577,1502
MS_C5_Z=1415
MS_Z2=3153,1291
MS_M_Z2=2735,2524
MS_C_Z2=2320,2241
MS_C2_Z2=2141,2029
MS_C3_Z2=1901,1744
MS_C4_Z2=1577,1509
MS_C5_Z2=1415
Fno_FOR_ISO=-1
SS_FOR_ISO=-1
YLEVEL_FOR_ISO=-1

Advertisement