Preparation

Step 1.1 Choosing the installation
location
Overview of installation location requirements
125 mm
or more
(recommended)
Drain hose hole
You can select the direction of
draining (left or right).
Maximum pipe height: 8 m
Maximum pipe length: 15 m
Make at least one round to
reduce noise and vibration.
The actual units may look different from
the images depicted here.
Model
Minimum Maximum Maximum
AC026/035MNADKH
AC052MNADKH
AC071MNADKH
AC100MNTDEH
Outdoor
Unit
CAUTION
Outer wall
Indoor
Unit
Cut insulation to have
rainwater drained
100 mm or more
(recommended)
125 mm
or more
(recommended)
(Unit : m)
Pipe length
Pipe height
3
20
15
3
30
20
3
50
30
Make a U-trap (A) on the
pipe (which is connected to
the indoor unit) at outer wall
and cut the bottom part of
the insulation (about 10 mm)
to prevent rainwater from
getting inside through the
insulation.
Step 1.2 Checking and preparing
accessories and tools
Accessories
Accessories in the indoor unit package
ACMNADKH
Installation plate (1)
026/035
(01 frame)
Installation plate (1)
071
(05 frame)
Remote control battery (2)
Installation Manual (1)
Remote Control Holder (1)
Guide Left(1)
Installation plate (1)
052
(04 frame)
Remote control (1)
User Manual (1)
Cap screw (3)
M4 x 16
Tapped Screws (2)
Guide Right(1)
English
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ac***mntdeh

Table of Contents