Arc Suppression; Installing The Real Time Clock (Rtc) Backup Battery; First Time Use; Mounting The Ixp20 Controller - impro IXP20 Installation Manual

Table of Contents

Advertisement

Arc Suppression

Snubber devices are recommended for EMF Flyback and Arc Suppression when
driving an inductive load with the Relay, see Figure 2.

Installing the Real Time Clock (RTC) Backup Battery

CAUTION:
Remove the Battery Tab for the Real Time Clock from the Battery
Holder IMMEDIATELY BEFORE powering up the IXP20 Controller.
DO NOT remove the Battery Tab after applying power to the IXP20.

First Time Use

1.
Ensure that power is NOT applied to the Controller.
2.
Locate the removable Battery Tab.
3.
Pull the removable Battery Tab out of the Battery Holder.
4.
Immediately apply power to the Controller.
Replacement
NOTE:
Because of the delicacy of this procedure, we recommend you contact your
distributor before trying to replace the Battery.

Mounting the IXP20 Controller

CAUTION:
Make certain that you mount the Controller on a vibration-free
surface.
NOTE:
You can mount the IXP20 Controller onto virtually any surface including
metal.
Select the mounting position of the IXP20 Controller, considering accessibility, routing
of wires and visibility of the Thin Film Transistor Liquid Crystal Display (TFT-LCD) and
accessibility of the Keypad.
Secure the enclosure to the mounting surface, using four suitable screws and wall
plugs, nuts and bolts or rivets.
ISC304-0-0-GB-06
Figure 2: EMF Flyback and Arc Suppression