Terminal Communication; Reader Options; Relays; Digital Inputs - impro IXP20 Installation Manual

Table of Contents

Advertisement

Terminal Communication

RS485 Terminal Port
Electrical Interface ..................
Baud Rate ..............................
Data Format ...........................
Communications Protocol ......
Line Termination (RS485) ......

Reader Options

Reader 1 Wiegand and Reader 2 Wiegand allows connection to the ImproX (MDR)
Multi-discipline Reader and Wiegand Readers. The function is selectable via the DIP-
switches (See Table 1).
Power Output ...............................
Modes Supported ........................
Electrical Interface .......................
Communications Protocol ..........

Relays

Relay Output ................................
Relay Contact Ratings .................
Operations ....................................

Digital Inputs

General
Type .............................................
Detection Resistance Range ......
Protection Range .........................
ISC304-0-0-GB-06
RS485.
38 400.
8 data bits, no parity, 1 stop bit.
ImproX Secure Communications Protocol.
Provision is made for line termination.
12 V DC and 5 V DC (selectable) at maximum
200 mA.
Tag + PIN-code or Reason Code.
TTL Full Duplex.
ImproX Proprietary Protocol.
2 Relays, Form C, each with NO, COM and
NC contacts.
10 A at 28 V DC,
5 A at 220 V AC,
10 A at 120 V AC.
100 000 Minimum.
4 Dry-contact inputs.
< 2 kOhm.
+15 V continuous.