SPECIFICATIONS
Working Environment .................
Passive Frequency ......................
RF Frequency ...............................
Security ........................................
Input Voltage ................................
Power Requirements
Input Voltage 12 V DC,
1 Antenna Reader, all
Relays OFF ............................
Input Voltage 12 V DC,
1 Antenna Reader, all
Relays ON ..............................
Relays
Relay Output ..........................
Relay Contact Ratings ...........
Installer Interfaces
LED Indicators
7-Segment Display .........
Push-buttons ..........................
X S
INSTALLATION MANUAL
The SupaGate is designed to work in an
indoor or protected outdoor environment
similar to IP20. The SupaGate is, therefore,
NOT sealed against water.
125 kHz.
433.92 MHz.
ImproX DCT, Dynamic Code Transmission
Technology.
10 V DC to 14 V DC.
Current (mA)
60
220
4 Relays, each with NO, COM and NC
contacts.
10 A at 28 V DC,
5 A at 220 V AC.
2 Displays, Red (externally visible).
4 Push-buttons (externally accessible).
MODEL NUMBER: SGI911-1-1-GB-XX
G
UPA
ATE
Power (W)
0.72
2.64

Advertisement

loading

Summary of Contents for impro IMPROX SUPAGATE SGI911-1-1-GB-XX

  • Page 1 MODEL NUMBER: SGI911-1-1-GB-XX MPRO ImproX SupaGate 4-Channel Controller INSTALLATION MANUAL SPECIFICATIONS Working Environment ....The SupaGate is designed to work in an indoor or protected outdoor environment similar to IP20. The SupaGate is, therefore, NOT sealed against water. Passive Frequency ...... 125 kHz.
  • Page 2 INSTALLATION INFORMATION Accessories Find the following when unpacking the SupaGate Controller: A SupaGate housed in a Black tinted, Polycarbonate Plastic Cabinet. The SupaGate consists of a 2-piece Top Cover and a Base. CAUTION: DO NOT use the Metal-oxide Varistors (25 Vrms, 500 A, 77 V max clamping) with mains power applications.
  • Page 3 Figure 1: Button Configuration for ImproX (QT) Quad Transmitter Programmed in “Dynamic Code Transmission Mode” The ImproX (QT) Quad Transmitter has its own passive Tag, separate from the transmitted codes. Presenting the ImproX (QT) Quad Transmitter passive Tag to Antenna Reader 1 drives Relay 1. Relay 1 Relay 2 Relay 3...
  • Page 4 MOUNTING THE SUPAGATE CAUTION: DO NOT mount the Controller on or close to a metal surface. CAUTION: Mount the SupaGate in a suitable indoor location, or protected outdoor location. Mounting the SupaGate in a location unprotected against rain will damage the SupaGate Controller. CAUTION: Make certain that you mount the Controller on a vibration-free surface.
  • Page 5 After removing the SupaGate from its packaging, straighten the flexible Antenna, this ensures an improved RF read range. Position the SupaGate in clear line-of-sight, preferably 1.50 m to 2 m (5 ft to 6 ft) above the ground, in the direction of movement, with the Antenna vertical. Secure the Cabinet to the mounting surface, using two suitable screws and wall plugs (supplied) nuts and bolts or rivets.
  • Page 6 Figure 5 shows a typical connection diagram for the SupaGate. Figure 5: Typical SupaGate Electrical Connections SGI300-0-0-GB-08 April 2008 Page 6...
  • Page 7 USER INFORMATION 7-Segment Display LED Mode and Action Display Displays Duration POWER-UP 2 seconds then enters Run Mode RUN MODE Rotates in a circular Reading Tags manner Unknown Tag 2 seconds Tag Found Displays the Tag 2 seconds Memory Location (01-99) PROGRAMMING MODE 1 second...
  • Page 8 7-Segment Display LED Mode and Action Display Displays Duration Adding RF Tags 1 second In Run Mode press the “ADD” Push- button for less than 1 second. Press the “TENS” and “UNITS” Push- Displays the first free 2 seconds buttons until the desired Tag Location is Location (01-99) shown.
  • Page 9 7-Segment Display LED Mode and Action Display Displays Duration Adding Special (5-Digit) PIN-codes 1 second The PIN-code entered activates only the Relay specified as the 5 digit of the PIN- code. Displays the first free 2 seconds In Run Mode press the “ADD” Push- Location (01-99) button for less than 1 second.
  • Page 10 7-Segment Display LED Mode and Action Display Displays Duration Replacing Lost Tags Displays the first free 2 seconds Location Delete the lost Tag from its Tag Location. (See the “Deleting Tags” (01-99) section). Displays selected Tag Add the new Tag to the abovementioned Memory Location Tag Location.
  • Page 11 COMPLICATED CONCEPTS If the Tag + PIN-code function is required, then register a Tag at Antenna Reader 1 and a 5-digit PIN-code specifying Relay 2. Relays 1 and 2 can then be wired in series. Appropriate Relay durations need to be chosen. If the incorrect PIN-code is entered 3 times in succession, the Keypad locks for 20 seconds.
  • Page 12 TAG LOCATIONS Document all Tag owners at their respective Tag Memory Locations (in the SupaGate) using Table 2. This list provides an easy reference when you need to delete Tags from the SupaGate. Relay or PIN-code Relay or PIN-code Owner Owner SGI300-0-0-GB-08 April 2008...
  • Page 13 Relay or PIN-code Relay or PIN-code Owner Owner Table 2: Tag Location Table Blank Space SGI300-0-0-GB-08 April 2008 Page 13...
  • Page 14 We reserve the right to nullify the products guarantee or warranty where you have not properly installed the Metal-oxide Varistors. This product conforms to our Guarantee or Warranty details placed on our Web Site to read further please go to www.impro.net. USER NOTES SGI300-0-0-GB-08...
  • Page 15 USER NOTES SGI300-0-0-GB-08 April 2008 Page 15...
  • Page 16 This manual is applicable to the ImproX SupaGate 4-Channel Controller, SGI911-1-1-GB-01. (The last two digits of the stock code indicate the issue status of the product). ImproX SupaGate\English Manuals\LATEST SGI300-0-0-GB-08 Issue 09 Apr 2008 ISSUE\XSupGate-insm-en-09.docx SGI300-0-0-GB-08 April 2008 Page 16...