I
MPRO
ImproX SupaGate 4-Channel Controller
SPECIFICATIONS
Working Environment .................
Passive Frequency ......................
RF Frequency ...............................
Security ........................................
Input Voltage ................................
Power Requirements
Input Voltage 12 V DC,
1 Antenna Reader, all
Relays OFF ............................
Input Voltage 12 V DC,
1 Antenna Reader, all
Relays ON ..............................
Relays
Relay Output ..........................
Relay Contact Ratings ...........
Installer Interfaces
LED Indicators
7-Segment Display .........
Push-buttons ..........................
X S
INSTALLATION MANUAL
The SupaGate is designed to work in an
indoor or protected outdoor environment
similar to IP20. The SupaGate is, therefore,
NOT sealed against water.
125 kHz.
433.92 MHz.
ImproX DCT, Dynamic Code Transmission
Technology.
10 V DC to 14 V DC.
Current (mA)
60
220
4 Relays, each with NO, COM and NC
contacts.
10 A at 28 V DC,
5 A at 220 V AC.
2 Displays, Red (externally visible).
4 Push-buttons (externally accessible).
MODEL NUMBER: SGI911-1-1-GB-XX
G
UPA
ATE
Power (W)
0.72
2.64