IXP110 C
SPECIFICATIONS
Working Environment .................
Power Requirements
Input Voltage using a Sealed
Lead Acid Backup Battery,
Connected to the Battery Input
and or Strike Lock Connected
to the Power Output ...............
Input Voltage NOT using a
Sealed Lead Acid Backup
Battery and or Strike Lock ......
IXP110 with two Antenna
Readers Connected ...............
ONTROLLER
ImproX IXP110 Controller
INSTALLATION MANUAL
Designed to work in an indoor (dry)
environment similar to IP40. The Controllers
are NOT sealed against water.
14 V AC to 18 V AC.
18 V DC to 24 V DC.
9 V AC to 18 V AC.
9 V DC to 24 V DC.
NOTE:
NOTE:
135 mA (2.43 W).
NOTE:
NOTE:
NOTE:
NOTE:
MODEL NUMBER: IXP904-1-0-GB-XX
Battery Charging Voltage and
Power Output Voltage are set at
between 13.6 V DC and 13.8 V DC.
This current is measured using
18 V DC Input Voltage.
Each Relay draws an extra
120 mA.
The IXP110 current limits the
charging current into the Sealed
Lead Acid Battery to a maximum of
350 mA.
The maximum size Sealed Lead
Acid Battery that can connect to the
Battery Input is 12 V, 7 Ahr.
The maximum current that can be
drawn from the Power Output is
250 mA. (If using a Maglock or
high current Strike Lock, connect
the Lock to a separate power
supply).
IXP905-1-0-GB-XX
IXP906-1-0-GB-XX
XEA901-1-0-GB-XX
XEA902-1-0-GB-XX
xea

Advertisement

loading

Summary of Contents for impro IXP904-1-0-GB Series

  • Page 1 MODEL NUMBER: IXP904-1-0-GB-XX IXP905-1-0-GB-XX IXP906-1-0-GB-XX IXP110 C ONTROLLER XEA901-1-0-GB-XX XEA902-1-0-GB-XX ImproX IXP110 Controller INSTALLATION MANUAL SPECIFICATIONS Working Environment ....Designed to work in an indoor (dry) environment similar to IP40. The Controllers are NOT sealed against water. Power Requirements Input Voltage using a Sealed Lead Acid Backup Battery, Connected to the Battery Input 14 V AC to 18 V AC.
  • Page 2 Ethernet Port Configuration ......Standard Ethernet RJ45 connector. 10/100 Mbps, half or full duplex. RS232 Port Configuration ......9-Way, D-type, male connector at 115 200 Baud. USB Port Configuration ......USB, Type-B, female connector, USB 2.0 compliant 12 Mbps. Relays Relay Output ......
  • Page 3: Installation Information

    Controller Interfaces Status LED ......Green LED (externally visible). Antenna Reader Interfaces Status Indicator Status LED ..... Bi-colour, Red or Green LED. Buzzer Volume and Tone ... 4-Step adjustable volume, single tone. INSTALLATION INFORMATION Accessories Find the following when unpacking the ImproX IXP110 Controller: An IXP110 Controller housed in a Black, Aluminium extruded Cabinet.
  • Page 4 EARTH Connection Connect the IXP110 Controller to a good EARTH point. Using the Power Input Port, connect the EARTH Lead to the ‘ETH’ Terminal. Mains EARTH can be used, but electrical noise may exist. Antenna Readers Antenna Reader Distance The ideal cable distance between the IXP110 Controller and its Antenna Reader ranges between 2 m to 16 m (7 ft to 53 ft).
  • Page 5 Mounting the Controller CAUTION: Make certain that you mount the Controller on a vibration-free surface. Select the mounting position of the IXP110 Controller, considering accessibility, routing of wires and visibility of the LED. Secure the Base to the mounting surface, using four suitable screws and wall plugs (supplied), nuts and bolts or rivets.
  • Page 6: Electrical Connections

    Installing the Real Time Clock (RTC)/RAM Backup Battery CAUTION: When handling the Real Time Clock (RTC)/RAM Backup Battery, be careful NOT to touch the Positive and Negative Poles simultaneously. Doing so will discharge the Battery. The Battery Holder is located on the left-hand side of the Controller’s Printed Circuit Board (PCB), alongside the RTE Input Terminal Block (see Figure 5).
  • Page 7 Connecting the IXP110 Controller Figure 6: Input and Power Connections IXP343-0-0-GB-07 April 2009 Page 7...
  • Page 8 Figure 7: Antenna Reader and Relay Connections IXP343-0-0-GB-07 April 2009 Page 8...
  • Page 9 IXP110 System Maintenance Deleting the Database If it becomes necessary to clear all Tagholders, including all Tagholder settings, follow these steps: Figure 8: Deleting the Database Restore Factory Defaults If it becomes necessary to return the IXP110 System to its factory default settings, follow these steps: Figure 9: Restoring Factory Defaults Blank Space...
  • Page 10: Guarantee Or Warranty

    We reserve the right to nullify the products guarantee or warranty where you have not properly installed the Metal-oxide Varistors. This product conforms to our Guarantee or Warranty details placed on our Web Site, to read further please go to www.impro.net. USER NOTES IXP343-0-0-GB-07...
  • Page 11 USER NOTES IXP343-0-0-GB-07 April 2009 Page 11...
  • Page 12 This manual is applicable to the ImproX IXP110 Controller, IXP904-1-0-GB-02, IXP905-1-0-GB-02 and IXP906-1-0-GB-03. (The last two digits of the Impro stock code indicate the issue status of the product). IXP110\Controller\English Manuals\LATEST IXP343-0-0-GB-07 Issue 08 Apr 2009 ISSUE\IXP110C-insm-en-08.docx IXP343-0-0-GB-07 April 2009...