IXP20 C

SPECIFICATIONS

Working Environment
Plastic Housing ............................
Power
Input Voltage ................................
Power Requirements (ISC920)
12 V DC with no peripherals
connected and relays off ........
24 V DC with no peripherals
connected and relays off ........
Power Requirements (ISC921)
12 V DC with no peripherals
connected and relays off ........
24 V DC with no peripherals
connected and relays off ........
Relay Power Requirements ........
Real Time Clock (RTC) Backup
Battery
Battery Type ...........................
Battery Life .............................
Controller Communication
Ethernet Port ................................
ONTROLLER
ImproX IXP20 Controller
INSTALLATION MANUAL
Designed to work in an indoor (dry)
environment similar to IP40. The Controller is
not sealed against water.
10 V DC to 30 V DC, polarity sensitive.
Current (mA)
75
40
130
60
An additional ~0.4 W per Relay in use.
1 x 3 V, CR2032, Lithium cell Battery.
1 year with power OFF,
5 years with Power ON,
5 years Storage with Battery Tab in place.
Standard Ethernet RJ45 connector.
10/100 Base T, half or full duplex.
MODEL NUMBER: ISC920-0-0-GB-XX
Power (W)
0.90
0.96
1.56
1.44
ISC921-5-0-GB-XX

Advertisement

Table of Contents
loading

Summary of Contents for impro IXP20

  • Page 1 MODEL NUMBER: ISC920-0-0-GB-XX ISC921-5-0-GB-XX IXP20 C ONTROLLER ImproX IXP20 Controller INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing ......Designed to work in an indoor (dry) environment similar to IP40. The Controller is not sealed against water. Power Input Voltage ........
  • Page 2 Terminal Communication RS485 Terminal Port Electrical Interface ....RS485. Baud Rate ......38 400. Data Format ......8 data bits, no parity, 1 stop bit. Communications Protocol ..ImproX Secure Communications Protocol. Line Termination (RS485) ..Provision is made for line termination. Reader Options Reader 1 Wiegand and Reader 2 Wiegand allows connection to the ImproX (MDR) Multi-discipline Reader and Wiegand Readers.
  • Page 3 Read Capability ......Slim Tags, Omega Tags, Mifare® Standard, Mifare® Ultralite, FeliCa, Desfire, HID iClass, WriTag 128 and WriTag 2048. CAUTION: The IXP20 System does not support the use of HID 1346 Proxkey II Tags. NOTE: HID, FeliCa and MIFARE® are...
  • Page 4 Continuous Red on connection to network. INSTALLATION INFORMATION Accessories CAUTION: The IXP20 Controller needs a standard Ethernet cable to connect to a PC. We do NOT however supply this cable with the Controller’s accessories. Find the following when unpacking the ImproX IXP20 Controller: ...
  • Page 5 Readers at least 500 mm (20 in) apart. EARTH Connection Connect the IXP20 Controller to a good EARTH point. Using the RS485 Port, connect the ETH Lead to the „ETH‟ Terminal. Mains EARTH can be used, but electrical noise may exist.
  • Page 6 Remove the Battery Tab for the Real Time Clock from the Battery Holder IMMEDIATELY BEFORE powering up the IXP20 Controller. DO NOT remove the Battery Tab after applying power to the IXP20. First Time Use Ensure that power is NOT applied to the Controller.
  • Page 7 NOTE: Because of the way standard Wiegand Readers handle HID Tag codes, IXP20 Sites using standard Wiegand Readers can only support one of two options: HID Tags only or any other Tag type (that is Slim Tags, Omega Tags, Mifare® Standard, Mifare® Ultralite, FeliCa, Desfire, WriTag 128 and WriTag 2048 depending on the Reader).
  • Page 8 DIP-switch Position Connections Wiegand Open Format. If the ImproX RF is connected, then Button 1 of the ImproX (QT) Quad Transmitter reports. If the ImproX RF is connected, then Button 2 of the ImproX (QT) Quad Transmitter reports. If the ImproX RF is connected, then Button 3 of the ImproX (QT) Quad Transmitter reports.
  • Page 9 Controller discards the tag code.  If the IXP20 Controller expects a PIN-code and receives a number greater than 65535, then the Controller assumes the number to be a tag code. The Controller discards the previously read Tag for the current one and the Controller will still expect a PIN-code.
  • Page 10 ELECTRICAL CONNECTIONS Key Component Positions Figure 3: IXP20 Controller Key Component Positions ISC304-0-0-GB-06 April 2011 Page 10...
  • Page 11 Connecting the IXP20 Controller Figure 4 shows a typical electrical connection diagram for the IXP20 Controller. Figure 4: Typical IXP20 Controller Electrical Connections ISC304-0-0-GB-06 April 2011 Page 11...
  • Page 12 Figure 5: IXP20 Controller connected to Wiegand Reader ISC304-0-0-GB-06 April 2011 Page 12...
  • Page 13 Figure 6: IXP20 Controller connected to ImproX RF ISC304-0-0-GB-06 April 2011 Page 13...
  • Page 14 UNIT ADDRESS INFORMATION Fixed Address Once the IXP20 Controller is installed, sketch a rough site plan. Attach the loose (additional Fixed Address Label packaged with the Controller) Fixed Address Label in the position of the Controller on the sketched site plan. When the system installation is complete and all the units are represented on the site plan by their Fixed Address Labels, file the site plan for future reference.
  • Page 15 MAC Address Figure 7: Sample MAC Address Label Each IXP20 Controller is supplied with a separate MAC Address Label, much like the one shown in Figure 7, which uniquely identifies each Controller. Attach the extra loose MAC Address Label, alongside the Fixed Address Label, to the Unit Location Chart enclosed (or your sketched site plan).
  • Page 16 Fixed Address Label Unique Location Description ISC304-0-0-GB-06 April 2011 Page 16...
  • Page 17 Fixed Address Label Unique Location Description ISC304-0-0-GB-06 April 2011 Page 17...
  • Page 18 Fixed Address Label Unique Location Description ISC304-0-0-GB-06 April 2011 Page 18...
  • Page 19 We reserve the right to nullify the products guarantee or warranty where you have not properly installed the Metal-oxide Varistors. This product conforms to our Guarantee or Warranty details placed on our Web Site, to read further please go to www.impro.net. USER NOTES ISC304-0-0-GB-06...
  • Page 20 This manual is applicable to the ImproX IXP20 Controller, ISC920-0-0-GB-03 and ISC921-5-0-GB-03. (The last two digits of the Impro stock code indicate the issue status of the product). IXP20\Controller\English Manuals\LATEST ISC304-0-0-GB-06 Issue 07 2011 ISSUE\ IXP20iTR-insm-en-07.docx ISC304-0-0-GB-06 April 2011 Page 20...

Table of Contents