End Of Line (Eol) Sensing Circuit - impro IXP20 Installation Manual

Table of Contents

Advertisement

NOTE:
End of Line (EOL) Sensing enables the Controller to raise an alarm when
somebody tampers with the circuit (that is, cutting or shorting the wires)
between either Reader 1 Inputs DOS [1] or Reader 2 Inputs DOS [1] and
GROUND (GND). In other words the Controller distinguishes between
tampering on the circuit, and the door being in an actual 'Normally Open'
state.
By placing Resistors into the circuit between either Reader 1 Inputs DOS [1]
or Reader 2 Inputs DOS [1] and GROUND (GND), the Controller's Digital
Input monitors a constant resistance through the circuit. When the circuit is
tampered with, the Resistors are bypassed; the Controller detects the
resistance change raising an alarm.
Door Lock
Type ......................................
Protection Range ...................
General
Frequency ....................................
Read Capability ............................
Controller Diagnostic Indicators
Buzzer
Volume and Tone ...........
ISC304-0-0-GB-06
Figure 1: End of Line (EOL) Sensing Circuit
2 Dry-contact inputs.
+15 V continuous.
125 kHz and 13.56 MHz.
Slim Tags, Omega Tags, Mifare® Standard,
Mifare® Ultralite, FeliCa, Desfire, HID iClass,
WriTag 128 and WriTag 2048.
CAUTION:
The IXP20 System does not
support the use of HID 1346
Proxkey II Tags.
NOTE:
HID, FeliCa and MIFARE® are
registered trademarks of HID
Global Corporation (an ASSA
ABLOY Group Brand), The Sony
Corporation and Koninklijke Phillips
Electronics N.V. respectively.
Single tone, with a 3-step adjustable volume.