Adjusting Voltage Limits - MacDon FD75 Operator's Manual

Flexdraper combine header
Hide thumbs Also See for FD75:
Table of Contents

Advertisement

4. Use a voltmeter (A) to measure voltage between
ground (Pin 2) and signal (Pin 3) wires at AHHC sensor
in float indicator box. Ensure it is at high voltage limit for
combine. Refer to Table
NOTE:
The harness connector must be plugged into sensor.
5. Fully lower combine feeder house, and float header up
off down stops (float indicator should be at 4, and
adapter should be fully separated from header).
NOTE:
You may need to hold HEADER DOWN switch for a few
seconds to ensure feeder house is fully lowered.
6. Use a voltmeter (A) to measure voltage between
ground and signal wires at AHHC sensor in float
indicator box. It should be at low voltage limit for
combine. Refer to Table
NOTE:
The harness connector must be plugged into sensor.
7. Adjust voltage limits (refer to
page
105) if sensor voltage is not within low and high
limits or if range between low and high limits is
insufficient. Refer to Table

Adjusting Voltage Limits

NOTE:
The auto header height control (AHHC) sensor assemblies used for CLAAS and some New Holland combines are
slightly different from sensor assemblies used for other combine models—all three assemblies are illustrated in this
procedure.
214323
OPERATION
3.13, page
103.
3.13, page
103.
Adjusting Voltage Limits,
3.13, page
103.
Figure 3.127: Measuring Voltage at Float
Indicator Box
Figure 3.128: Measuring Voltage at Float
Indicator Box