GREER Company MICROGUARD 424 Operation/Troubleshooting Operation/Troubleshooting Manual

Rated capacity
Hide thumbs Also See for MICROGUARD 424:

Advertisement

Greer Company
Greer Company
Greer Company
Greer Company
RATED CAPACITY INDICATOR SYSTEM
RATED CAPACITY INDICATOR SYSTEM
RATED CAPACITY INDICATOR SYSTEM
RATED CAPACITY INDICATOR SYSTEM
OPERATION/TROUBLESHOOTING
OPERATION/TROUBLESHOOTING
OPERATION/TROUBLESHOOTING
OPERATION/TROUBLESHOOTING
1918 EAST GLENWOOD PLACE, SANTA ANA CA 92705
MICROGUARD
424 OPERATION/TROUBLESHOOTING MANUAL
Crane Systems
MICROGUARD
MICROGUARD
MICROGUARD
MICROGUARD
MANUAL
MANUAL
MANUAL
MANUAL
TELESCOPIC BOOM CRANES
TELESCOPIC BOOM CRANES
TELESCOPIC BOOM CRANES
TELESCOPIC BOOM CRANES
HORIZONTAL DISPLAY
HORIZONTAL DISPLAY
HORIZONTAL DISPLAY
HORIZONTAL DISPLAY
424
424
424
424
Tel:(714) 259-9702 Fax:(714) 259-7626
PN W424103 REV A 02/13/01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MICROGUARD 424 and is the answer not in the manual?

Questions and answers

Tom Cook
May 19, 2025

I am a rookie of the crane world. We have a Grove RT-740 crane with a Microguard 424 system in it. We cannot get the boom to come all the way down to traveling height. The buzzer comes on and boom stops.

1 comments:
Mr. Anderson
May 23, 2025

The boom of a Grove RT-740 crane with a MicroGuard 424 system may not lower to traveling height and may trigger a buzzer if the system detects an overload or unsafe condition. The MicroGuard 424 continuously monitors crane functions using sensors and compares the actual load and boom configuration with stored capacity chart data. If the system senses that the boom angle, height, or load exceeds safe limits (such as exceeding MAX. HEIGHT or other set alarms), it can activate audible and visual warnings and may cause function kick-out to prevent further movement.

This answer is automatically generated

Summary of Contents for GREER Company MICROGUARD 424

  • Page 1 Greer Company Greer Company Greer Company Greer Company Crane Systems MICROGUARD MICROGUARD MICROGUARD MICROGUARD  RATED CAPACITY INDICATOR SYSTEM RATED CAPACITY INDICATOR SYSTEM RATED CAPACITY INDICATOR SYSTEM RATED CAPACITY INDICATOR SYSTEM OPERATION/TROUBLESHOOTING OPERATION/TROUBLESHOOTING OPERATION/TROUBLESHOOTING OPERATION/TROUBLESHOOTING MANUAL MANUAL MANUAL MANUAL TELESCOPIC BOOM CRANES...
  • Page 2 Greer Company Greer Company Greer Company Crane Systems The Greer Company is dedicated to the design and manufacture of electronic parts created to aid in crane operation and in the protection of crane operators and associated personnel. This manual has been...
  • Page 3: Table Of Contents

    Greer Company Greer Company Greer Company Greer Company Crane Systems MICROGUARD MICROGUARD MICROGUARD MICROGUARD  RATED CAPACITY INDICATOR SYSTEM RATED CAPACITY INDICATOR SYSTEM RATED CAPACITY INDICATOR SYSTEM RATED CAPACITY INDICATOR SYSTEM OPERATION/TROUBLESHOOTING MANUAL OPERATION/TROUBLESHOOTING MANUAL OPERATION/TROUBLESHOOTING MANUAL OPERATION/TROUBLESHOOTING MANUAL TABLE OF CONTENTS...
  • Page 4: Microguard 424 System Description

    Greer Company Greer Company Greer Company Greer Company Crane Systems MICROGUARD 424 SYSTEM DESCRIPTION   This manual describes the function and operation of the MicroGuard 424 Rated Capacity Indicator (RCI)  System for telescopic boom cranes. The MicroGuard 424 System is intended to aid the crane operator in efficient crane operation by continuously monitoring the load and warning of an approach to an overload or a two-block condition.
  • Page 5: Display Windows

    Greer Company Greer Company Greer Company Greer Company Crane Systems DISPLAY WINDOWS LEFT DISPLAY WINDOW LEFT DISPLAY WINDOW LEFT DISPLAY WINDOW LEFT DISPLAY WINDOW MAXIMUM RATED CAPACITY is a digital display of the maximum permitted capacity. M i cr oG uar d It is derived from the crane's capacity chart.
  • Page 6: Display Windows

    Greer Company Greer Company Greer Company Greer Company Crane Systems DISPLAY WINDOWS RIGHT SIDE DISPLAYS RIGHT SIDE DISPLAYS RIGHT SIDE DISPLAYS RIGHT SIDE DISPLAYS The RADIUS/HEIGHT display gives a continuous indication of the radius of the load, which is the horizontal distance from the 57.2...
  • Page 7: Push Buttons - Icons - Lamps - Alarms

    Greer Company Greer Company Greer Company Greer Company Crane Systems PUSH BUTTONS PUSH BUTTONS - - - - ICONS ICONS - - - - LAMPS LAMPS - - - - ALARMS ALARMS PUSH BUTTONS PUSH BUTTONS ICONS ICONS LAMPS LAMPS...
  • Page 8 Greer Company Greer Company Greer Company Greer Company Crane Systems OPERATOR ALARM BUTTON OPERATOR ALARM BUTTONS AND CONTRAST S AND CONTRAST OPERATOR ALARM BUTTON OPERATOR ALARM BUTTON S AND CONTRAST S AND CONTRAST VIEW is a push button used during the setting of operator alarms. It is used to start the routine and to view the current alarm settings.
  • Page 9 Greer Company Greer Company Greer Company Greer Company Crane Systems UPPER RIGHT DISPLAY UPPER RIGHT DISPLAY UPPER RIGHT DISPLAY UPPER RIGHT DISPLAY The RADIUS/HEIGHT icon indicates the area of the display that gives a readout of radius and height. This icon is also a push button used to select the alternate display of height.
  • Page 10 Greer Company Greer Company Greer Company Greer Company Crane Systems LOWER RIGHT PUSH BUTTONS AND ICONS LOWER RIGHT PUSH BUTTONS AND ICONS LOWER RIGHT PUSH BUTTONS AND ICONS LOWER RIGHT PUSH BUTTONS AND ICONS DEDUCT ERECTED STOWED SELECT 1 and 3 UP/DOWN ARROWS are push buttons used as arrows for scrolling.
  • Page 11: Microguard 424 System Operation

    Greer Company Greer Company Greer Company Greer Company Crane Systems MICROGUARD 424 SYSTEM OPERATION SYSTEM OPERATION  SYSTEM OPERATION SYSTEM OPERATION  At start-up, the MicroGuard 424 System automatically performs a self-test. Upon completion of the self-test, the System goes directly to the normal working screen. The self-test can be initiated at any time during normal operation by pressing the TEST button.
  • Page 12: Configuration Selection

    Greer Company Greer Company Greer Company Greer Company Crane Systems CONFIGURATION SELECTION CONFIGURATION SELECTION CONFIGURATION SELECTION CONFIGURATION SELECTION  In the normal operational mode, the MicroGuard 424 System is programmed to retain the configuration last selected. Each time the system is powered up, it will automatically choose that configuration. Only when the crane is rigged differently must a new configuration be selected.
  • Page 13 Greer Company Greer Company Greer Company Greer Company Crane Systems STOWED DEDUCTS STOWED DEDUCTS STOWED DEDUCTS STOWED DEDUCTS When attachments such as flys are stowed, it is necessary to make a reduction in the rated capacity of the crane. This reduction, also called a deduct, is specified in the capacity chart. The MG424 has the ability to store this data and to make the deduct from the chart.
  • Page 14 Greer Company Greer Company Greer Company Greer Company Crane Systems CONFIGURATION SELECTION (Link-Belt Model 70 shown) START THE SELECTION OF CRANE CONFIGURATION BY PRESSING "CRANE SET UP" CRANE SET UP SCROLL TO CARRIER OUTRIGGERS ON TIRES PICK AND RIGGING FULLY EXT.
  • Page 15 Greer Company Greer Company Greer Company Greer Company Crane Systems SCROLL TO REAR WINCH LIFTING POINT +35' OFSET +35' OFSET +35' OFSET +35' TELE +35' TELE +35' TELE ATTACHMENT FLY 2° FLY 15° FLY 30° FLY 2° FLY 15° FLY 30°...
  • Page 16: Examples Of Crane Set Up

    Greer Company Greer Company Greer Company Greer Company Crane Systems CRANE SET CRANE SET- - - - UP EXAMPLES UP EXAMPLES CRANE SET CRANE SET UP EXAMPLES UP EXAMPLES MAIN BOOM ♦ FULLY EXTENDED OUTRIGGERS ♦ COUNTERWEIGHT ATTACHED ♦ PICKING FROM THE MAIN BOOM WITH THE FRONT WINCH, 6 PARTS OF LINE ♦...
  • Page 17: Main Boom Plus 35' Offsettable Fly

    Greer Company Greer Company Greer Company Greer Company Crane Systems CRANE SET RANE SET- - - - UP EX UP EXAMPLES AMPLES RANE SET RANE SET UP EX UP EX AMPLES AMPLES MAIN BOOM PLUS 35' OFFSETTABLE FLY ♦ FULLY EXTENDED OUTRIGGERS ♦...
  • Page 18: Main Boom Plus 48' Telescoping Fly

    Greer Company Greer Company Greer Company Greer Company Crane Systems CRANE SET CRANE SET CRANE SET CRANE SET- - - - UP EXAMPLES UP EXAMPLES UP EXAMPLES UP EXAMPLES MAIN BOOM PLUS 48' TELESCOPING FLY ♦ FULLY EXTENDED OUTRIGGERS ♦...
  • Page 19: On Tires

    Greer Company Greer Company Greer Company Greer Company Crane Systems CRANE SET CRANE SET- - - - UP EXAMPLES UP EXAMPLES CRANE SET CRANE SET UP EXAMPLES UP EXAMPLES ON TIRES ♦ PICK AND CARRY CENTERED OVER REAR ♦ COUNTERWEIGHT REMOVED ♦...
  • Page 20: Rigging/Travel Mode

    Greer Company Greer Company Greer Company Greer Company Crane Systems CRANE SET CRANE SET CRANE SET CRANE SET- - - - UP EXAMPLES UP EXAMPLES UP EXAMPLES UP EXAMPLES RIGGING/TRAVEL MODE The Rigging /Travel mode is selected as part of the carrier options. This mode is used to facilitate the rigging and travel of the crane by inhibiting motion-cut and audible alarm while selected.
  • Page 21: Operator Settable Alarms

    Greer Company Greer Company Greer Company Greer Company Crane Systems OPERATOR SETTABLE ALARMS OPERATOR SETTABLE ALARMS OPERATOR SETTABLE ALARMS OPERATOR SETTABLE ALARMS  An additional feature of the MicroGuard 424 System is the provision of Operator Settable Alarms. These alarms, when properly set by the operator, provide a method of obstacle avoidance. This is achieved by means of minimum and maximum angle, maximum length and maximum height alarms.
  • Page 22: Method Of Setting

    Greer Company Greer Company Greer Company Greer Company Crane Systems METHOD OF SETTING METHOD OF SETTING METHOD OF SETTING METHOD OF SETTING WARNING THE FOLLOWING EXAMPLES ARE GIVEN TO ILLUSTRATE METHODS OF SETTING ALARMS. THE ACTUAL VALUES GIVEN SHOULD NOT BE USED WITHOUT FIRST CHECKING THE CAPACITY CHART TO ENSURE SAFE, STABLE OPERATION UNDER THE CONDITIONS DESCRIBED.
  • Page 23: Examples Of Setting Alarms

    Greer Company Greer Company Greer Company Greer Company Crane Systems EXAMPLES OF SETTING THE ALARMS SETTING THE ALARMS SETTING THE ALARMS SETTING THE ALARMS Setting the alarm point is achieved by positioning the crane at the point at which the alarm is to sound and then, when in the operator alarm screen, using the SET push button to set the alarm.
  • Page 24: Canceling Alarms

    Greer Company Greer Company Greer Company Greer Company Crane Systems EXAMPLE D EXAMPLE D EXAMPLE D EXAMPLE D To have an alarm whenever the boom tip height exceeds 75 feet, use the following procedure: 1. Extend the boom and/or adjust the boom angle so that the tip height is 75 feet.
  • Page 25: Periodic Inspections

    Greer Company Greer Company Greer Company Greer Company Crane Systems PERIODIC INSPECTIONS PERIODIC INSPECTIONS PERIODIC INSPECTIONS PERIODIC INSPECTIONS CHECKING THE ANTI TWO BLOCK SYSTEM CHECKING THE ANTI TWO BLOCK SYSTEM CHECKING THE ANTI TWO BLOCK SYSTEM CHECKING THE ANTI TWO BLOCK SYSTEM...
  • Page 26: Routine Maintenance

    Greer Company Greer Company Greer Company Greer Company Crane Systems SYSTEM CHECKS SYSTEM CHECKS SYSTEM CHECKS SYSTEM CHECKS ♦ Check that the displayed boom angle agrees with the measured angle. ♦ Check that the displayed radius agrees with the measured operating radius.
  • Page 27 Greer Company Greer Company Greer Company Greer Company Crane Systems MICROGUARD MICROGUARD MICROGUARD MICROGUARD  OPERATION/TROUBL OPERATION/TROUBL OPERATION/TROUBL OPERATION/TROUBLESHOOTING MANUAL ESHOOTING MANUAL ESHOOTING MANUAL ESHOOTING MANUAL TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS SECTION 2: TROUBLESHOOTING FAULT DIAGNOSTIC PROCEDURES......................
  • Page 28 Greer Company Greer Company Greer Company Greer Company Crane Systems PARTS REPLACEMENT ..........................43-45 PRESSURE TRANSDUCERS ......................43 EXTENSION REEL..........................43 BOOM ANGLE SENSOR HTC8660 ONLY ..................43 BOOM ANGLE SENSOR........................44 EXECUTIVE ROM CHIP........................44 PERSONALITY ROM CHIP ........................44 DUTY ROM CHIP ..........................
  • Page 29: Section 2: Troubleshooting

    Greer Company Greer Company Greer Company Greer Company Crane Systems FAULT CODES FAULT CODES FAULT CODES FAULT CODES TROUBLESHOOTING TROUBLESHOOTING TROUBLESHOOTING TROUBLESHOOTING GROUP “A” ANALOG SENSORS CODE FAULT DIAGNOSTIC PROCEDURES FAULT DIAGNOSTIC PROCEDURES FAULT DIAGNOSTIC PROCEDURES FAULT DIAGNOSTIC PROCEDURES ...
  • Page 30: Group "A" Fault Codes

    Greer Company Greer Company Greer Company Greer Company Crane Systems MicroGuard AAA B CC DD TEST 0 0 0 0 0 0 100% CRANE STOWED WORKING SET UP DEDUCT A REA PRESS AND HOLD DEDUCT ERECTED STOW ED FAULT CODES...
  • Page 31 Greer Company Greer Company Greer Company Greer Company Crane Systems Fault 3 Fault 3 Fault 3 Fault 3 Fault 10 Fault 10 Fault 10 Fault 10 AAA B CC DD AAA B CC DD 003 0 00 00 010 0...
  • Page 32: Power Supply Voltages

    Greer Company Greer Company Greer Company Greer Company Crane Systems POWER SUPPLY VOLTAGES POWER SUPPLY VOLTAGES POWER SUPPLY VOLTAGES POWER SUPPLY VOLTAGES The Computer Unit contains 2 major boards, the B atter y + Terminal Connection Board and the Computer Board.
  • Page 33: Accessing The Computer And Termination Boards

    Greer Company Greer Company Greer Company Greer Company Crane Systems ACCESSING MAIN COMPUTER BOARD ACCESSING MAIN COMPUTER BOARD ACCESSING MAIN COMPUTER BOARD ACCESSING MAIN COMPUTER BOARD each cable, one at a time, checking the Analog Drive Voltage after each cable is connected.
  • Page 34: Pressure Channel Fault Guide

    Greer Company Greer Company Greer Company Greer Company Crane Systems PRESSURE CHANNEL FAULT GUIDE PRESSURE CHANNEL FAULT GUIDE PRESSURE CHANNEL FAULT GUIDE PRESSURE CHANNEL FAULT GUIDE transducers. With no pressure, the upper display should indicate 0+/-20 bits. FUNCTIONAL TESTS A fault in a pressure transducer is such that a fault on 6.
  • Page 35: Transducer Resistance Measurement

    Greer Company Greer Company Greer Company Greer Company Crane Systems PRESSURE CHANNEL FAULT GUIDE PRESSURE CHANNEL FAULT GUIDE PRESSURE CHANNEL FAULT GUIDE PRESSURE CHANNEL FAULT GUIDE TRANSDUCER RESISTANCE MEASUREMENT TRANSDUCER RESISTANCE MEASUREMENT TRANSDUCER RESISTANCE MEASUREMENT TRANSDUCER RESISTANCE MEASUREMENT PRESSU RE TRA N SD U CER CO N N ECTO R...
  • Page 36: Analog Drive Voltage

    Greer Company Greer Company Greer Company Greer Company Crane Systems 4. With the DVM set to the Ohms range, measure the resistance between pins B, C, D, E, and the case of + D R the transducer. Measure the resistance between B,...
  • Page 37: Boom Extension Sensor Ain2

    Greer Company Greer Company Greer Company Greer Company Crane Systems BOOM EXTENSION SENSOR AIN2 BOOM EXTENSION SENSOR AIN2 BOOM EXTENSION SENSOR AIN2 BOOM EXTENSION SENSOR AIN2 Refer to the MicroGuard 414 wiring details in the Installation Manual for the model of crane under test.
  • Page 38: Boom Angle Sensor Ain3

    Greer Company Greer Company Greer Company Greer Company Crane Systems BOOM ANGLE SENSOR AIN3 BOOM ANGLE SENSOR AIN3 BOOM ANGLE SENSOR AIN3 BOOM ANGLE SENSOR AIN3 12. With the negative lead of the voltmeter connected to blue, drive negative and the positive lead of the 1.
  • Page 39: Swing Potentiometer Ain5 And Ain6

    Greer Company Greer Company Greer Company Greer Company Crane Systems SWING POTENTIOMETER SWING POTENTIOMETER SWING POTENTIOMETER SWING POTENTIOMETER AIN5 AND AIN6 AIN5 AND AIN6 AIN5 AND AIN6 AIN5 AND AIN6 A I N 5 and A I N 6, + D R...
  • Page 40: No Duty Found

    Greer Company Greer Company Greer Company Greer Company Crane Systems NO DUTY FOUND NO DUTY FOUND NO DUTY FOUND NO DUTY FOUND CURRENT DUTY BAD CURRENT DUTY BAD CURRENT DUTY BAD CURRENT DUTY BAD This fault indicates failure of the Duty Chip IC3 on the The system needs the same information that the Main Computer Board.
  • Page 41: Anti Two-Block System

    Greer Company Greer Company Greer Company Greer Company Crane Systems ANTI TWO BLOCK SYSTEM ANTI TWO BLOCK SYSTEM ANTI TWO BLOCK SYSTEM ANTI TWO BLOCK SYSTEM 4. Remove the brown wire connected to ATB in terminal of the digital input group. The system should...
  • Page 42: Anti Two-Block Logic Levels

    Greer Company Greer Company Greer Company Greer Company Crane Systems ANTI TWO ANTI TWO- - - - BLOCK LOGIC LEVELS BLOCK LOGIC LEVELS ANTI TWO ANTI TWO BLOCK LOGIC LEVELS BLOCK LOGIC LEVELS D O U T1 C O N TRO LS TH E A 2B...
  • Page 43: Parts Replacement

    Greer Company Greer Company Greer Company Greer Company Crane Systems PARTS REPLACEMENT PARTS REPLACEMENT PARTS REPLACEMENT PARTS REPLACEMENT approximately 12 ft. At this point there will be no pre- tension. PRESSURE TRANSDUCER REPLACEMENT PRESSURE TRANSDUCER REPLACEMENT PRESSURE TRANSDUCER REPLACEMENT PRESSURE TRANSDUCER REPLACEMENT 7.
  • Page 44: Boom Angle Sensor

    Greer Company Greer Company Greer Company Greer Company Crane Systems BOOM ANGLE SENSOR REPLACEMENT BOOM ANGLE SENSOR REPLACEMENT BOOM ANGLE SENSOR REPLACEMENT BOOM ANGLE SENSOR REPLACEMENT 2. With the power off, remove IC7 (the Personality ROM Chip) from its socket. Refer to General Chip To replace the Boom Angle Sensor that is fitted inside Removal and Installation (page 45) in this manual.
  • Page 45: Computer Box

    Greer Company Greer Company Greer Company Greer Company Crane Systems 4. Loosen the two screws holding the Computer 5. Install the new computer and secure with the four backing plate to the box. mounting screws. 5. Remove the Computer Board Assembly.
  • Page 46: Glossary

    Greer Company Greer Company Greer Company Greer Company Crane Systems GLOSSARY OF TERMS GLOSSARY OF TERMS GLOSSARY OF TERMS GLOSSARY OF TERMS ABORT The premature termination of a data entry procedure. ALARM A signal that warns or alerts such as a flashing light or loud noise.
  • Page 47 Greer Company Greer Company Greer Company Greer Company Crane Systems ELASTIC Capable of recovering size or shape after deformation. ERECTED An attachment on the main boom fitted in its working position. ATTACHMENT EXTENSION SENSOR A device which measures the extension of the telescoping sections of a boom.
  • Page 48 Greer Company Greer Company Greer Company Greer Company Crane Systems "Read only" memory from which data can only be read, i.e. not changed after programming. ROPE LIMIT The maximum permitted single line pull determined by the construction and diameter of a wire rope.
  • Page 49: Computer Board Layout

    Greer Company Greer Company Greer Company Greer Company Crane Systems COMPUTER BOARD LAYOUT COMPUTER BOARD LAYOUT COMPUTER BOARD LAYOUT COMPUTER BOARD LAYOUT I C2 I C3 I C8 I C7 EX EC D U TY RA M PERS LA YO U T O F M A I N CO M PU TER BO A RD...
  • Page 50: Termination Board Layout

    Greer Company Greer Company Greer Company Greer Company Crane Systems TERMINATION BOARD TERMINATION BOARD TERMINATION BOARD TERMINATION BOARD DIN1 DOUT0 DIN2 AIN0 DOUT1 O'LOAD DIN3 AIN1 DOUT2 DIN4 DOUT3 DIN5 DOUT4 DIN6 DOUT5 DIN7 AIN2 DOUT6 DIN8 AIN3 DOUT7 DIN9...
  • Page 51: Extension Reel Layout

    Greer Company Greer Company Greer Company Greer Company Crane Systems EXTENSION REEL LAYOUT A ngl e Sensor D at a Pot ’ r Ter m i nal A 220210 P010110 St r i p 1918 EAST GLENWOOD PLACE, SANTA ANA, CA 92705...
  • Page 52 Greer Company Greer Company Greer Company Greer Company Crane Systems 1918 East Glenwood Place Santa Ana, CA 92705 Telephone: (714) 259-9702 Fax (714) 259-7626 1918 East Glenwood Place Santa Ana, CA 92705 Telephone: (714) 259-9702 Fax: (714) 259-7626 1918 EAST GLENWOOD PLACE, SANTA ANA CA 92705...