CHIP PROTECTION FROM TWO-BLOCK OR OVERLOAD. ALL CRANE OPERATIONS ARE AT THE SOLE DISCRETION OF THE OPERATOR. GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A & M414380C PN W424104- 11/23/99...
The switch is located near the center of the computer board between and below the ribbon cable connectors. CAL SWITCH GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A &...
POWER TO THE SYSTEM SHOULD BE SWITCHED OFF BEFORE INSERTING OR REMOVING ANY INTEGRATED CIRCUITS. FAILURE TO OBSERVE THIS PRECAUTION MAY CAUSE PERMANENT DAMAGE TO THE SYSTEM OR ITS COMPONENTS AND RESULT IN THE LOSS OF CALIBRATION DATA. GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 ...
This procedure completely erases all previous data from the A personality. There is an opportunity to ABORT the procedure at this point by first pressing . Follow by pressing SELECT to erase the memory. GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 ...
START THE COMMAND BY PRESSING SELECT THE SYSTEM WILL EXECUTE A SELF-TEST AND DISPLAY FAULT CODES EXIT FROM THE ROUTINE BY PRESSING GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A & M414380C PN W424104- 11/23/99...
NO DUTY FOUND FAULT 2 CURRENT DUTY BAD FAULT 4 CONFIGURATION NOT CALIBRATED GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A & M414380C PN W424104- 11/23/99...
After entry of all digits, decimal point and sign changes, move the cursor to E using and press SELECT to terminate the sequence. • GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 ...
AFTER THE ENTRY OF FIVE DIGITS, THE CURSOR WILL MOVE AUTOMATICALLY TO IF LESS THAN FIVE DIGITS HAVE BEEN ENTERED, USE TO MOVE THE CURSOR TO GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 ...
♦ With the pressure transducers open to atmosphere, calibrate the zero of the piston and rod pressure transducers using the sequence ON THE FOLLOWING PAGE. GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 ...
Page 12
(or abort with THE DISPLAY WILL READ Tx.1 = 0 (zeroed input) EXIT FROM THE ROUTINE BY PRESSING Reconnect all hydraulic lines before resuming crane operation. GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A &...
THE DISPLAY WILL READ No.2 = 0 (zeroed input) EXIT THE ROUTINE BY PRESSING. OR CHANGE SENSOR BY PRESSING (Continue Next Page) GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A & M414380C PN W424104- 11/23/99...
THE DISPLAY WILL READ No.3 = 0 (zeroed input) EXIT FROM THE ROUTINE BY PRESSING OR CHANGE SENSOR BY PRESSING GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A & M414380C PN W424104- 11/23/99...
CONFIRM THE CALIBRATION (or abort with THE DISPLAY WILL READ No.3 I/P = XX.XX boom angle entered) EXIT FROM THE ROUTINE BY PRESSING GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A & M414380C PN W424104- 11/23/99...
At this stage of the procedure the boom length display will indicate the extension value that you entered. After completion of Command 07, main boom radius/moment, it will display boom length. Retract the boom and continue the procedure. GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 ...
CONFIRM SELECTION OF 1 SLEW ZERO Continued BY PRESSING SELECT next page GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A & M414380C PN W424104- 11/23/99...
Page 18
BY PRESSING SELECT SELECT CONFIRM THE CALIBRATION (or abort with EXIT THE ROUTINE BY PRESSING GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A & M414380C PN W424104- 11/23/99...
To return to normal operation, use CRANE SET UP. GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 ...
Page 20
FLY 2° FLY 15° FLY 30° FLY 2° FLY 15° FLY 30° GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A & M414380C PN W424104- 11/23/99...
LOAD DISPLAY WILL READ ZERO. RAISE THE CALIBRATION LOAD. THE DISPLAY SHOULD READ THE EXACT VALUE OF THE CALIBRATION LOAD ENTERED. EXIT THE ROUTINE BY PRESSING GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A &...
SELECT LOW ANGLE DATA BY PRESSING USE THE NUMBER ENTRY ROUTINE TO ENTER THE CURRENT RADIUS THE DISPLAY WILL READ ( GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A & M414380C PN W424104- 11/23/99...
Page 23
Some models with Mode A may have booms fully extended at this point. If that is the case then continue with Command 8 BDC. Otherwise continue with this procedure on the next page. GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 ...
Page 24
Continue the calibration routine with Command 08, BDC. If there is a Manual section or Mode B equipped on the crane return to Command 07 after completing the BDC for the Main Boom. GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 ...
Page 25
LOW ANGLE DATA BY PRESSING SELECT USE THE NUMBER ENTRY ROUTINE TO ENTER THE CURRENT RADIUS THE DISPLAY WILL READ ( GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A & M414380C PN W424104- 11/23/99...
Page 26
RAISE THE HOOK BLOCK. THEN STORE THE LOW ANGLE DATA BY PRESSING SELECT USE THE NUMBER ENTRY ROUTINE TO ENTER THE NEW RADIUS THE DISPLAY WILL READ ( GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 ...
Page 27
CONFIRM THE CALIBRATION BY PRESSING SELECT (or abort with EXIT FROM THE ROUTINE BY PRESSING Continue the calibration routine with Command 08, BDC. GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A & M414380C PN W424104- 11/23/99...
When this message occurs as a result of requiring the acquisition of data below 60°, the data may be entered using the key to indicate at which unusual angle data is being acquired. GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 ...
SELECT CONFIRM THE CALIBRATION BY PRESSING (or abort with EXIT FROM THE ROUTINE WITHOUT CALIBRATING BY PRESSING GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A & M414380C PN W424104- 11/23/99...
(See Note below) NOTE: If any change was made to either one of these Commands, it is recommended that Command 01/0 "SAVE" be completed also. GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 ...
PRESSING d on next AFTER THE MESSAGE "CALIBRATING" =Exit page GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A & M414380C PN W424104- 11/23/99 31 of 44...
Page 32
THE DISPLAY WILL READ Continued EXIT THE ROUTINE BY PRESSING on next page GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A & M414380C PN W424104- 11/23/99...
Page 33
% SWL 1 = 90.000 SCROLL TO % SWL #2 BY PRESSING THE DISPLAY WILL READ % SWL 2 = 90.000 EXIT FROM THE ROUTINE BY PRESSING GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A &...
ROPE LIMIT 1 = 11.700 EXIT FROM THE ROUTINE BY PRESSING NOTE: If there were any changes to Rope Limits, complete Command 01/0 "SAVE" also. GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 ...
(or abort with CHANGE THE SETTING BY PRESSING COMPLETE THE CALIBRATION BY PRESSING SELECT EXIT THE ROUTINE BY PRESSING GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A & M414380C PN W424104- 11/23/99...
(or abort with SEE NOTE AFTER THE MESSAGE, "CALIBRATING," EXIT BY PRESSING SWITCH OFF POWER TO THE SYSTEM GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A & M414380C PN W424104- 11/23/99...
Page 37
THE COPY OF THE CALIBRATION PERSONALITY IS NOW RESTORED TO THE "A" SECTION OF IC7. IT SHOULD NOW BE SAVED TO THE "B" SECTION USING THE COMMAND 1/0 SAVE GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 ...
NOT USED ATB IN HI = NO ALARM NOT USED NOT USED GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A & M414380C PN W424104- 11/23/99...
The adjustment of the graduation of sensors. CAPACITY CHART A table, supplied by the crane manufacturer, showing the specifications and ratings for each individual crane. GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 ...
Page 40
An attachment on the main boom in working (not stowed) position. ATTACHMENT EXTENSION SENSOR A device that measures the extension of the telescoping sections of a boom. GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A &...
Page 41
MICROPROCESSOR A computer processor contained on an integrated chip. MILLIVOLT One thousandth of a volt. GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A & M414380C PN W424104- 11/23/99...
Page 42
The maximum permitted single line pull determined by the construction and diameter of a wire rope. SAVE To move data from the working Personality to a ‘write protected’ area of memory. GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 MicroGuard 424 GENERIC Calibration Procedure for Programs M414371A &...
Page 43
A device that is actuated by energy from one system and converts this to another form for use by a different system (as a loudspeaker that is actuated by electrical signals and supplies acoustic power). GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 ...
Page 44
An area of memory in a computer that cannot be accessed by a microprocessor for data entry or change . ZERO The ZERO point on a graduated scale. GREER COMPANY 1918 EAST GLENWOOD PLACE SANTA ANA, CALIFORNIA 92705 TEL: 714)259-9702 FAX: 259-9702 ...