Specification - Sealey Sac9001 Instructions Manual

Air conditioner/dehumidifier 9000btu/hr
Table of Contents

Advertisement

do not connect or disconnect the plug from the mains with wet hands.
8
Always discard the water from the collection tank, do not use it for any other purpose.
9
Place the unit on a level and stable surface.
9
to prevent water from freezing, do not use the unit at ambient temperatures below 0°c.
9
do not use the unit outside.
8
Ensure that heating appliances are not exposed to the flow of air from the unit.
9
Before attempting to move the unit, empty the contents of the water tank. see section 8 for instructions on moving.
9
switch off and disconnect unit from the mains before attempting any cleaning or other maintenance work.
9
ensure that the unit is turned off correctly when not in use, and stored in a safe, dry area, out of reach of children. see section 9.
9
note: this appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of
the appliance in a safe way and understand the hazards involved. children shall not play with the appliance. cleaning and user
maintenance shall not be made by children without supervision.
2. introduction
thermostatically controlled unit with extendible exhaust hose and window kit - ideal for home or office environments. Features two-speed
fan and electronic remote control. Air conditioning temperature range 17-30°c. Also features a dehumidifying function capable of removing
up to 24ltr/day. Refrigerant is R410A. Mounted on castors for manoeuvrability. Cable storage keeps unit tidy when not in use.

3. Specification

model no:. . . . . . . . . . . . . . . . . . . . . . . . . . . . Sac9001
cooling Capacity: . . . . . . . . . . . . . . . . . . . . .9000Btu/hr
supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V
Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 999W
maximum Air Flow:. . . . . . . . . . . . . . . . . . . . .380mtr³/hr
maximum Water Extraction Rate:. . . . . . . . . . . 24ltr/day
refrigerant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . r410A
discharge Side Pressure.. . . . . . . . . . . . . . . . 3.6MPa
suction side Pressure . . . . . . . . . . . . . . . . . . . 1.2mPa
exhaust Hose length. . . . . . . . . . . . . . . . . . . .1500mm
energy class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22kg
1. control panel.
2. Horizontal louvre.
3. Vertical louvre.
4. Air outlet frame.
5. Vertical Louvre connecting lever.
6. Caster.
7. Top cap.
8. Horizontal louvre connecting lever.
9. main vertical louvre.
10. front shell.
11. Handle / Remote Control Storage.
12. Back shell.
13. retaining clamp.
14. Power cord.
© Jack sealey limited
15. Air duct.
16 Wire-winding posts.
17. drain cap.
18. Evaporator filter mesh.
19. Evaporator filter frame.
20. Radiating fine mesh.
21. Condenser filter mesh.
22. Condenser filter frame.
23. Base plate.
24. Window sealing board assembly.
25. Window sealing board.
26. Exhaust Hose.
27. connector.
28. remote control.