3-in-1 High capacity, compact, portable air conditioner, air cooling with ventilation and dehumidifying functions. Thermostatically controlled
with built-in 24hr timer and sleep mode. Soft-touch control panel with LED digital display and remote control. Self-evaporating system
reuses the moisture it collects from the air to help with the cooling process allows better efficiency, low maintenance and powerful cooling.
Water-full indicator with auto-shut-off. Supplied with extendable exhaust ducting with window kit for ventilation and continuous drain hose.
Dehumidifying function capable of removing up to 14.6L/day. Eco-Friendly R290 refrigerant. Air conditioning temperature range 16-32°C.
Washable filter. Auto-defrost function at low ambient temperature. Mounted on castor wheels for manoeuvrability.

3. SPECIFICATION

Model No.: ..............................................................SAC7000
Cooling Capacity: ..................................................7000Btu/hr
Discharge Side Pressure: ..........................................3.2MPa
Energy Rating: .................................................... A (EER:2.6)
IP Rating: ....................................................................... IPX1
Mass of Refrigerant: ....................................................... 120g
Maximum Airflow: .....................................................290m³/hr
Maximum Exhaust Hose Length: ................................... 1.5m
Maximum Water Extraction Rate: ........................... 14.6L/day
Noise Level: .............................................................. 65db(A)
Power: ...........................................................................780W
Rated Capacity: ..........................................................2050W
Refrigerant: ................................................................... R290
Suction Side Pressure:...............................................0.7MPa
Supply: ................................................................ 230V~50Hz
4. CONTENTS

5. INSTALLATION

Unpack the product and check contents. Should there be any damaged or missing parts contact your supplier immediately.
5.1.
LOCATION
5.1.1.
Place the appliance on a firm, level surface.
5.1.2.
Ensure that there is a clear area of at least 500mm around the appliance (fig.2) to allow for
adequate air circulation.
DO NOT operate the appliance in close proximity to walls, curtains or other objects that may
8
block the air inlet or outlet.
WARNING! DO NOT locate the appliance where it is subject to:
Heat sources such as radiators, ovens or similar
Direct sunlight
Mechanical vibration or shock
Excessive dust
Lack of ventilation i.e., inside a cabinet or bookcase
Uneven surfaces
5.2.
ASSEMBLE THE EXHAUST HOSE
WARNING! The air conditioning unit must be vented to outside. This ensures that any heat and moisture is removed from the
designated room space.
5.2.1.
Screw fit the hose connector to one end of the exhaust hose (fig.3).
5.2.2.
Screw fit the window kit adapter to the other end of the exhaust hose (fig.4).
© Jack Sealey Limited
Model No.: ........................................................ SAC9000.V3
Cooling Capacity: ..................................................9000Btu/hr
Discharge Side Pressure: ..........................................3.2MPa
Energy Rating: .................................................... A (EER:2.6)
IP Rating: ....................................................................... IPX1
Mass of Refrigerant: ....................................................... 170g
Maximum Airflow: .....................................................330m³/hr
Maximum Exhaust Hose Length: ................................... 1.5m
Maximum Water Extraction Rate: .............................. 25L/day
Noise Level: .............................................................. 65db(A)
Power: .........................................................................1005W
Rated Capacity: ..........................................................2600W
Refrigerant: ................................................................... R290
Suction Side Pressure:...............................................0.7MPa
Supply: ................................................................ 230V~50Hz
ITEM
1
2
3
4
5
6
7
8
9
10
11
12
fig.1
13
Original Language Version
DESCRIPTION
Control panel
Air outlet with adjustable louvre
Handle
Air inlet and filter
Castor wheel
Drainage hole
Air exhaust
ACCESSORIES
Exhaust hose
Hose connector
Window kit adaptor
Remote control
Window kit
Drain hose (not shown)