Specification; Installation - Sealey SAC12000.V5 Instruction Manual

12,000btu/hr portable air conditioner/dehumidifier/air cooler/heater with window sealing kit

Advertisement

2.
INTRODUCTION
i
4-in1 high capacity, compact, portable air conditioner, air cooling with ventilation, dehumidifying and heating functions. Thermostatically
controlled with built-in 24hr timer and sleep mode. Soft-touch control panel with LED digital display and remote control. Self-evaporating
system reuses the moisture it collects from the air to help with the cooling process allows better efficiency, low maintenance and
powerful cooling. Water-full indicator with auto shut off. Supplied with extendable exhaust ducting with window kit for ventilation
and continuous drain hose. Eco-Friendly R290 refrigerant. Air conditioning temperature range 16-32°C. Washable filter. Auto-defrost
function at low ambient temperature. Mounted on castor wheels for manoeuvrability.

3. SPECIFICATION

MODEL NO: ................................................ SAC12000.V4
Cooling Capacity: .............................................12000Btu/hr
Discharge Side Pressure:........................................3.2MPa
Energy Rating: ................................................. A (EER:2.6)
IP rating....................................................................... IPX1
Mass of refrigerant: ..................................................... 240g
Max. airflow: ..........................................................410m³/hr
Max. exhaust hose length: .......................................... 1.5m
Max. water extraction rate: .................................. 30.3L/day
Noise level: ............................................................ 65dB(A)
Power: ........................... 1337W (Cooling) 1118W (Heating)
Rated capacity: .............3520W (Cooling) 2780W (Heating)
Refrigerant: ................................................................ R290
Suction side pressure: .............................................0.7MPa
Supply: ............................................................. 230V~50Hz
fig.1

4. INSTALLATION

IMPORTANT: Allow the refrigerant to settle for at least 24 hours before using the unit.
4.1.
EXHAUST HOSE ASSEMBLY
4.1.1.
Thread hose adaptor (fig.2) onto the hose and then locate adaptor into its housing in the body.
4.1.2.
Pull the free end out and screw the window adaptor onto the other end of the exhaust hose.
4.2.
WINDOW ADAPTOR
4.2.1.
Slide the window adaptor to the correct width for the window opening and tighten the wing nut (fig.3) to stop the slide closing.
4.2.2.
Close the window onto the window adaptor, clamping it in place. This can be achieved with sliding windows or vertically hinged
windows.
4.2.3.
Insert the hose adaptor into the window adaptor (fig.3, fig.4)
8
8
DO NOT use an extension hose or hose different from the one supplied. The length
8
and diameter of the hose supplied are the optimum size for this unit. Changing those dimensions
could affect the performance.
4.3.
ATTACH WINDOW KIT ASSEMBLY SEE ALSO SECTION 8 ON WINDOW KIT INCLUDED.
© Jack Sealey Limited
fig.2
Wingnut
fig.3
Original Language Version
Window
Fitting
fig.4
SAC12000.V5, SACWK1 Issue 1